Literature DB >> 24593710

Monte Carlo dosimetry for 103Pd, 125I, and 131Cs ocular brachytherapy with various plaque models using an eye phantom.

Marielle Lesperance1, M Martinov1, R M Thomson1.   

Abstract

PURPOSE: To investigate dosimetry for ocular brachytherapy for a range of eye plaque models containing(103)Pd, (125)I, or (131)Cs seeds with model-based dose calculations.
METHODS: Five representative plaque models are developed based on a literature review and are compared to the standardized COMS plaque, including plaques consisting of a stainless steel backing and acrylic insert, and gold alloy backings with: short collimating lips and acrylic insert, no lips and silicone polymer insert, no lips and a thin acrylic layer, and individual collimating slots for each seed within the backing and no insert. Monte Carlo simulations are performed using the EGSnrc user-code BrachyDose for single and multiple seed configurations for the plaques in water and within an eye model (including nonwater media). Simulations under TG-43 assumptions are also performed, i.e., with the same seed configurations in water, neglecting interseed and plaque effects. Maximum and average doses to ocular structures as well as isodose contours are compared for simulations of each radionuclide within the plaque models.
RESULTS: The presence of the plaque affects the dose distribution substantially along the plaque axis for both single seed and multiseed simulations of each plaque design in water. Of all the plaque models, the COMS plaque generally has the largest effect on the dose distribution in water along the plaque axis. Differences between doses for single and multiple seed configurations vary between plaque models and radionuclides. Collimation is most substantial for the plaque with individual collimating slots. For plaques in the full eye model, average dose in the tumor region differs from those for the TG-43 simulations by up to 10% for(125)I and (131)Cs, and up to 17% for (103)Pd, and in the lens region by up to 29% for (125)I, 34% for (103)Pd, and 28% for (131)Cs. For the same prescription dose to the tumor apex, the lowest doses to critical ocular structures are generally delivered with plaques containing (103)Pd seeds.
CONCLUSIONS: The combined effects of ocular and plaque media on dose are significant and vary with plaque model and radionuclide, suggesting the importance of model-based dose calculations employing accurate ocular and plaque media and geometries for eye plaque brachytherapy.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24593710     DOI: 10.1118/1.4864474

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Dosimetric comparison between realistic ocular model and other models for COMS plaque brachytherapy with 103Pd, 131Cs, and 125I radioisotopes.

Authors:  Atiyeh Ebrahimi-Khankook; Alireza Vejdani-Noghreiyan
Journal:  Radiat Environ Biophys       Date:  2018-06-07       Impact factor: 1.925

2.  Optic Disc Dose Comparison Between 125I and 103Pd Collaborative Ocular Melanoma Study (COMS) Plaques Based on Current Clinical Practice.

Authors:  Yongsook C Lee; Shih-Chi Lin; Yongbok Kim
Journal:  Cureus       Date:  2021-06-28

3.  Development of GATE Monte Carlo Code for Simulation and Dosimetry of New I-125 Seeds in Eye Plaque Brachytherapy.

Authors:  Payvand Taherparvar; Zeinab Fardi
Journal:  Nucl Med Mol Imaging       Date:  2021-01-11

4.  Gold nanoparticle-based brachytherapy enhancement in choroidal melanoma using a full Monte Carlo model of the human eye.

Authors:  Somayeh Asadi; Mehdi Vaez-zadeh; S Farhad Masoudi; Faezeh Rahmani; Courtney Knaup; Ali S Meigooni
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.