Literature DB >> 24593335

Invited article: radon and thoron intercomparison experiments for integrated monitors at NIRS, Japan.

M Janik1, T Ishikawa1, Y Omori1, N Kavasi1.   

Abstract

Inhalation of radon ((222)Rn) and its short-lived decay products and of products of the thoron ((220)Rn) series accounts for more than half of the effective dose from natural radiation sources. At this time, many countries have begun large-scale radon and thoron surveys and many different measurement methods and instruments are used in these studies. Consequently, it is necessary to improve and standardize technical methods of measurements and to verify quality assurance by intercomparisons between laboratories. Four international intercomparisons for passive integrating radon and thoron monitors were conducted at the NIRS (National Institute of Radiological Sciences, Japan). Radon exercises were carried out in the 24.4 m(3) inner volume walk-in radon chamber that has systems to control radon concentration, temperature, and humidity. Moreover, the NIRS thoron chamber with a 150 dm(3) inner volume was utilized to provide three thoron intercomparisons. At present, the NIRS is the only laboratory world-wide that has carried out periodic thoron intercomparison of passive monitors. Fifty laboratories from 26 countries participated in the radon intercomparison, using six types of detectors (charcoal, CR-39, LR 115, polycarbonate film, electret plate, and silicon photodiode). Eighteen laboratories from 12 countries participated in the thoron intercomparisons, using two etch-track types (CR-39 and polycarbonate) detectors. The tests were made under one to three different exposures to radon and thoron. The data presented in this paper indicated that the performance quality of laboratories for radon measurement has been gradually increasing. Results of thoron exercises showed that the quality for thoron measurements still needs further development and additional studies are needed to improve its measuring methods. The present paper provides a summary of all radon and thoron international intercomparisons done at NIRS from 2007 to date and it describes the present status on radon and thoron passive, one-time cycle monitors.

Entities:  

Year:  2014        PMID: 24593335     DOI: 10.1063/1.4865159

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  2 in total

1.  Use of a geographic information system (GIS) for targeting radon screening programs in South Dakota.

Authors:  Kimberlee J Kearfott; Zachary D Whetstone; Khwaja M Rafique Mir
Journal:  J Radiat Res       Date:  2015-10-15       Impact factor: 2.724

2.  Impact of Wind Speed on Response of Diffusion-Type Radon-Thoron Detectors to Thoron.

Authors:  Yasutaka Omori; Yuki Tamakuma; Eka Djatnika Nugraha; Takahito Suzuki; Miki Arian Saputra; Masahiro Hosoda; Shinji Tokonami
Journal:  Int J Environ Res Public Health       Date:  2020-05-02       Impact factor: 3.390

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.