The Evaluation of the Reliability of Periotest for Implant Stability Measurements: An In Vitro Study.

Hakan Bilhan1, Altug Cilingir2, Canan Bural1,3, Caglar Bilmenoglu1,2, Olcay Sakar1,3, Onur Geckili1,3.   

Abstract

Periotest (Medizintechnik Gulden, Modautal, Germany) is a widely accepted implant stability measurement method, although the reliability is not well known. The aim of this in vitro study was to investigate the reliability of the Periotest in implant stability measurements. Thirty implants were placed in 3 cow ribs. The stability of each implant was measured by insertion torque, resonance frequency analyses, and Periotest and then compared. The Periotest values (PTVs) were measured by 4 different examiners. The measurements were repeated twice in both the buccal and mesial directions, for each implant at 2-hour intervals and the intra- and interobserver reliability of Periotest was measured. Results showed that the intraobserver reliability of the Periotest was excellent for the buccal PTVs but fair to poor for the mesial PTVs. The interobserver reliability of the Periotest was excellent for the buccal PTVs but poor for the mesial PTVs. No significance was found between the PTVs and IT values (P = .803) and PTVs and ISQ values, whereas a 47.1% significant correlation was detected between the IT values and ISQ values (P = .009). The present study indicates that only Periotest measurements from buccal result in excellent intra- and interobserver reliability for the quantification of the implant stability.

Entities:  

Keywords:  Osstell; Periotest; dental implant; implant stability; in vitro model; insertion torque; resonance frequency analysis; statistics

Mesh:

Substances:

Year:  2014        PMID: 24593232     DOI: 10.1563/aaid-joi-D-13-00303

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  5 in total

1.  Intra- and inter-operator concordance of the resonance frequency analysis. A cross-sectional and prospective clinical study.

Authors:  Raquel Antequera-Diaz; Maria-Pilar Quesada-García; Cristina Vallecillo; Marta Vallecillo-Rivas; Esther Muñoz-Soto; Maria-Victoria Olmedo-Gaya
Journal:  Clin Oral Investig       Date:  2022-07-08       Impact factor: 3.573

2.  Photobiomodulation stimulates surrounding bone formation and increases stability of titanium alloy miniscrews in ovariectomized rats.

Authors:  Bruna Guimarães Martins; Vanessa Santos de Moura; Denise Nami Fujii; Aguinaldo Silva Garcez; Selly Sayuri Suzuki
Journal:  Lasers Med Sci       Date:  2022-04-14       Impact factor: 2.555

3.  Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study.

Authors:  Jungwon Lee; Se-Wook Pyo; Hyun-Jae Cho; Jung-Sub An; Jae-Hyun Lee; Ki-Tae Koo; Yong-Moo Lee
Journal:  J Periodontal Implant Sci       Date:  2020-02-18       Impact factor: 2.614

4.  New Dental Implant with 3D Shock Absorbers and Tooth-Like Mobility-Prototype Development, Finite Element Analysis (FEA), and Mechanical Testing.

Authors:  Avram Manea; Grigore Baciut; Mihaela Baciut; Dumitru Pop; Dan Sorin Comsa; Ovidiu Buiga; Veronica Trombitas; Horatiu Colosi; Ileana Mitre; Roxana Bordea; Marius Manole; Manuela Lenghel; Simion Bran; Florin Onisor
Journal:  Materials (Basel)       Date:  2019-10-21       Impact factor: 3.623

Review 5.  Effects of low-level laser therapy on the orthodontic mini-implants stability: a systematic review and meta-analysis.

Authors:  Ana Carolina de Figueiredo Costa; Thays Allane Cordeiro Maia; Paulo Goberlânio de Barros Silva; Lucas Guimarães Abreu; Delane Viana Gondim; Pedro César Fernandes Santos
Journal:  Prog Orthod       Date:  2021-02-15       Impact factor: 2.750

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.