Literature DB >> 24593142

Fibre-optical microendoscopy.

M Gu1, H Bao1, H Kang1.   

Abstract

Microendoscopy has been an essential tool in exploring micro/nano mechanisms in vivo due to high-quality imaging performance, compact size and flexible movement. The investigations into optical fibres, micro-scanners and miniature lens have boosted efficiencies of remote light delivery to sample site and signal collection. Given the light interaction with materials in the fluorescence imaging regime, this paper reviews two classes of compact microendoscopy based on a single fibre: linear optical microendoscopy and nonlinear optical microendoscopy. Due to the fact that fluorescence occurs only in the focal volume, nonlinear optical microendoscopy can provide stronger optical sectioning ability than linear optical microendoscopy, and is a good candidate for deep tissue imaging. Moreover, one-photon excited fluorescence microendoscopy as the linear optical microendoscopy suffers from severe photobleaching owing to the linear dependence of photobleaching rate on excitation laser power. On the contrary, nonlinear optical microendoscopy, including two-photon excited fluorescence microendoscopy and second harmonic generation microendoscopy, has the capability to minimize or avoid the photobleaching effect at a high excitation power and generate high image contrast. The combination of various nonlinear signals gained by the nonlinear optical microendoscopy provides a comprehensive insight into biophenomena in internal organs. Fibre-optical microendoscopy overcomes physical limitations of traditional microscopy and opens up a new path to achieve early cancer diagnosis and microsurgery in a minimally invasive and localized manner.
© 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.

Entities:  

Keywords:  Fibre-optical fluorescence imaging; microendoscopy; microsurgery

Mesh:

Year:  2014        PMID: 24593142     DOI: 10.1111/jmi.12119

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  6 in total

Review 1.  Techniques to assess bone ultrastructure organization: orientation and arrangement of mineralized collagen fibrils.

Authors:  Marios Georgiadis; Ralph Müller; Philipp Schneider
Journal:  J R Soc Interface       Date:  2016-06       Impact factor: 4.118

2.  Differential structured illumination microendoscopy for in vivo imaging of molecular contrast agents.

Authors:  Pelham Keahey; Preetha Ramalingam; Kathleen Schmeler; Rebecca R Richards-Kortum
Journal:  Proc Natl Acad Sci U S A       Date:  2016-09-12       Impact factor: 11.205

3.  Fiber-bundle microendoscopy with sub-diffuse reflectance spectroscopy and intensity mapping for multimodal optical biopsy of stratified epithelium.

Authors:  Gage J Greening; Haley M James; Amy J Powless; Joshua A Hutcheson; Mary K Dierks; Narasimhan Rajaram; Timothy J Muldoon
Journal:  Biomed Opt Express       Date:  2015-11-19       Impact factor: 3.732

4.  Confocal 3D reflectance imaging through multimode fiber without wavefront shaping.

Authors:  Szu-Yu Lee; Vicente J Parot; Brett E Bouma; Martin Villiger
Journal:  Optica       Date:  2022-01-14       Impact factor: 11.104

5.  A targeted illumination optical fiber probe for high resolution fluorescence imaging and optical switching.

Authors:  Anant Shinde; Sandeep Menon Perinchery; Vadakke Matham Murukeshan
Journal:  Sci Rep       Date:  2017-04-03       Impact factor: 4.379

6.  Real-time Brain Tumor imaging with endogenous fluorophores: a diagnosis proof-of-concept study on fresh human samples.

Authors:  Fanny Poulon; Johan Pallud; Pascale Varlet; Marc Zanello; Fabrice Chretien; Edouard Dezamis; Georges Abi-Lahoud; François Nataf; Baris Turak; Bertrand Devaux; Darine Abi Haidar
Journal:  Sci Rep       Date:  2018-10-05       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.