Literature DB >> 24590241

Optical coherence tomography provides images similar to histology and allows the performance of extensive measurements of drug-eluting metal stents in animal ureters.

P Kallidonis1, G C Kagadis, P Kitrou, A Tsamandas, I Kyriazis, I Georgiopoulos, D Karnabatidis, S Tsantis, D Liourdi, A Al-Aown, E Liatsikos.   

Abstract

Optical coherence tomography (OCT) images and histology images of metal stents (MSs) inserted in animal ureters were compared, and the reliability of an OCT-based automated method for the performance of quantitative evaluation of ureteral MSs was evaluated. A zotarolimus-eluting metal stent (ZES) and a bare metal stent (BMS) were inserted in each ureter of ten pigs and six rabbits. OCT was performed in unobstructed stented ureters. Histopathologic examination of the stented ureters embedded in glycol-methacrylate took place. Quadrants of OCT images were compared to their respective histologic images by employing two independent observers who delineated different layers in the quadrants of OCT images and correlated them to the respective histologic quadrants. Manual (integrated OCT device software) and automated measurements of the OCT images using an automated strut detection method were compared. The observers highly agreed on the delineation of urothelium from the lamina propria and the lamina propria from the muscle layer of the ureteral wall. The algorithm measurements were similar to the manual measurements, and the algorithm proved to be reliable in the evaluation of ureteral MSs. Significantly higher endothelial hyperplasia of the BMSs in comparison to the ZESs was also quantitatively demonstrated by the strut detection method. OCT proved to be a reliable method for the evaluation of ureteral MSs. OCT provided images of the stented ureteral lumen similar to light microscopy quality. Measurements of the stented ureter are reliably performed by the automated strut detection method.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24590241     DOI: 10.1007/s10103-014-1548-x

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  23 in total

1.  Automatic vessel lumen segmentation and stent strut detection in intravascular optical coherence tomography.

Authors:  Stavros Tsantis; George C Kagadis; Konstantinos Katsanos; Dimitris Karnabatidis; George Bourantas; George C Nikiforidis
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  A novel approach for quantitative analysis of intracoronary optical coherence tomography: high inter-observer agreement with computer-assisted contour detection.

Authors:  Shuzou Tanimoto; Gaston Rodriguez-Granillo; Peter Barlis; Sebastiaan de Winter; Nico Bruining; Ronald Hamers; Michiel Knappen; Stefan Verheye; Patrick W Serruys; Evelyn Regar
Journal:  Catheter Cardiovasc Interv       Date:  2008-08-01       Impact factor: 2.692

3.  Catheter-based intraluminal optical coherence tomography versus endoluminal ultrasonography of porcine ureter ex vivo.

Authors:  U L Mueller-Lisse; O A Meissner; M Bauer; C Weber; G Babaryka; C G Stief; M F Reiser; U G Mueller-Lisse
Journal:  Urology       Date:  2009-04-10       Impact factor: 2.649

Review 4.  Ureteral stents: past, present and future.

Authors:  Evangelos Liatsikos; Panagiotis Kallidonis; Jens-Uwe Stolzenburg; Dimitrios Karnabatidis
Journal:  Expert Rev Med Devices       Date:  2009-05       Impact factor: 3.166

5.  Application of paclitaxel-eluting metal mesh stents within the pig ureter: an experimental study.

Authors:  Evangelos N Liatsikos; Dimitrios Karnabatidis; George C Kagadis; Kostantinos Rokkas; Costas Constantinides; Nikolaos Christeas; Nikolaos Flaris; Theodore Voudoukis; Chrisoula D Scopa; Petros Perimenis; Kriton S Filos; George C Nikiforidis; Jens-Uwe Stolzenburg; Dimitrios Siablis
Journal:  Eur Urol       Date:  2006-06-14       Impact factor: 20.096

Review 6.  Application of optical coherence tomography in percutaneous coronary intervention.

Authors:  Takashi Kubo; Atsushi Tanaka; Hironori Kitabata; Yasushi Ino; Takashi Tanimoto; Takashi Akasaka
Journal:  Circ J       Date:  2012-07-31       Impact factor: 2.993

7.  Three-dimensional imaging of ureter with endoscopic optical coherence tomography.

Authors:  Hui Wang; Wei Kang; Hui Zhu; Gregory MacLennan; Andrew M Rollins
Journal:  Urology       Date:  2011-01-22       Impact factor: 2.649

8.  Evaluation of zotarolimus-eluting metal stent in animal ureters.

Authors:  Panagiotis Kallidonis; Panagiotis Kitrou; Dimitrios Karnabatidis; Iason Kyriazis; Christina Kalogeropoulou; Athanasios Tsamandas; Dimitrios J Apostolopoulos; Theofanis Vrettos; Despoina Liourdi; Stavros Spiliopoulos; Abdulrahman Al-Aown; Chrisoula D Scopa; Evangelos Liatsikos
Journal:  J Endourol       Date:  2011-09-09       Impact factor: 2.942

Review 9.  Optical coherence tomography endpoints in stent clinical investigations: strut coverage.

Authors:  Satoko Tahara; Daniel Chamié; Motaz Baibars; Chadi Alraies; Marco Costa
Journal:  Int J Cardiovasc Imaging       Date:  2011-03-11       Impact factor: 2.357

10.  Fluorescence cystoscopy with high-resolution optical coherence tomography imaging as an adjunct reduces false-positive findings in the diagnosis of urothelial carcinoma of the bladder.

Authors:  Joerg Schmidbauer; Mesut Remzi; Tobias Klatte; Matthias Waldert; Julian Mauermann; Martin Susani; Michael Marberger
Journal:  Eur Urol       Date:  2009-08-05       Impact factor: 20.096

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.