Literature DB >> 24589402

CT protocol review and optimization.

James M Kofler1, Dianna D Cody2, Richard L Morin3.   

Abstract

To reduce the radiation dose associated with CT scans, much attention is focused on CT protocol review and improvement. In fact, annual protocol reviews will soon be required for ACR CT accreditation. A major challenge in the protocol review process is determining whether a current protocol is optimal and deciding what steps to take to improve it. In this paper, the authors describe methods for pinpointing deficiencies in CT protocols and provide a systematic approach for optimizing them. Emphasis is placed on a team approach, with a team consisting of at least one radiologist, one physicist, and one technologist. This core team completes a critical review of all aspects of a CT protocol and carefully evaluates proposed improvements. Changes to protocols are implemented only with consensus of the core team, with consideration of all aspects of the CT examination, including image quality, radiation dose, patient care and safety, and workflow.
Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  CT; protocol; radiation dose

Mesh:

Year:  2014        PMID: 24589402     DOI: 10.1016/j.jacr.2013.10.013

Source DB:  PubMed          Journal:  J Am Coll Radiol        ISSN: 1546-1440            Impact factor:   5.532


  9 in total

1.  Pilot study of the multicentre DISCHARGE Trial: image quality and protocol adherence results of computed tomography and invasive coronary angiography.

Authors:  Gianluca De Rubeis; Adriane E Napp; Peter Schlattmann; Jacob Geleijns; Michael Laule; Henryk Dreger; Klaus Kofoed; Mathias Sørgaard; Thomas Engstrøm; Hans Henrik Tilsted; Alberto Boi; Michele Porcu; Stefano Cossa; José F Rodríguez-Palomares; Filipa Xavier Valente; Albert Roque; Gudrun Feuchtner; Fabian Plank; Cyril Štěchovský; Theodor Adla; Stephen Schroeder; Thomas Zelesny; Matthias Gutberlet; Michael Woinke; Mihály Károlyi; Júlia Karády; Patrick Donnelly; Peter Ball; Jonathan Dodd; Mark Hensey; Massimo Mancone; Andrea Ceccacci; Marina Berzina; Ligita Zvaigzne; Gintare Sakalyte; Algidas Basevičius; Małgorzata Ilnicka-Suckiel; Donata Kuśmierz; Rita Faria; Vasco Gama-Ribeiro; Imre Benedek; Teodora Benedek; Filip Adjić; Milenko Čanković; Colin Berry; Christian Delles; Erica Thwaite; Gershan Davis; Juhani Knuuti; Mikko Pietilä; Cezary Kepka; Mariusz Kruk; Radosav Vidakovic; Aleksandar N Neskovic; Iñigo Lecumberri; Ignacio Diez Gonzales; Balazs Ruzsics; Mike Fisher; Marc Dewey; Marco Francone
Journal:  Eur Radiol       Date:  2019-12-16       Impact factor: 5.315

2.  CT and MR Protocol Standardization Across a Large Health System: Providing a Consistent Radiologist, Patient, and Referring Provider Experience.

Authors:  Peter B Sachs; Kelly Hunt; Fabien Mansoubi; James Borgstede
Journal:  J Digit Imaging       Date:  2017-02       Impact factor: 4.056

3.  Compliance with AAPM Practice Guideline 1.a: CT Protocol Management and Review - from the perspective of a university hospital.

Authors:  Timothy P Szczykutowicz; Robert K Bour; Myron Pozniak; Frank N Ranallo
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

4.  Detection of unwarranted CT radiation exposure from patient and imaging protocol meta-data using regularized regression.

Authors:  Ruidi Chen; Ioannis Ch Paschalidis; Hiroto Hatabu; Vladimir I Valtchinov; Jenifer Siegelman
Journal:  Eur J Radiol Open       Date:  2019-06-05

5.  A comprehensive assessment of physical image quality of five different scanners for head CT imaging as clinically used at a single hospital centre-A phantom study.

Authors:  Patrizio Barca; Fabio Paolicchi; Giacomo Aringhieri; Federica Palmas; Daniela Marfisi; Maria Evelina Fantacci; Davide Caramella; Marco Giannelli
Journal:  PLoS One       Date:  2021-01-14       Impact factor: 3.240

Review 6.  Insight into the Molecular Imaging of Alzheimer's Disease.

Authors:  Abishek Arora; Neeta Bhagat
Journal:  Int J Biomed Imaging       Date:  2016-01-10

7.  Implementation and evaluation of a protocol management system for automated review of CT protocols.

Authors:  Joshua Grimes; Shuai Leng; Yi Zhang; Thomas Vrieze; Cynthia McCollough
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

8.  Individualization of computed tomography protocols for suspected pulmonary embolism: a national investigation of routines.

Authors:  Berit Dymbe; Elisabeth Vespestad Mæland; Jorunn Rønhovde Styve; Albertina Rusandu
Journal:  J Int Med Res       Date:  2020-04       Impact factor: 1.671

9.  Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study.

Authors:  Atul M Padole; Pallavi Sagar; Sjirk J Westra; Ruth Lim; Katherine Nimkin; Mannudeep K Kalra; Michael S Gee; Madan M Rehani
Journal:  Insights Imaging       Date:  2019-09-23
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.