Literature DB >> 24583694

Microarray based on autodisplayed Ro proteins for medical diagnosis of systemic lupus erythematosus (SLE).

Gu Yoo1, Ji-Hong Bong1, Sinyoung Kim2, Joachim Jose3, Jae-Chul Pyun4.   

Abstract

A microarray-based immunoassay for the detection of autoantibodies against Ro protein was developed using Escherichia coli with autodisplayed Ro proteins (Ro(+)-E. coli). Patient serum usually contains various antibodies against the outer membrane components of E. coli as well as autoantibodies against the Ro protein. Therefore, the conventional immunoassay based on Ro(+)-E. coli requires both wild type E. coli (blank test) and Ro(+)-E. coli, and both strains of E. coli must be prepared in situ for each individual test serum. In this study, we tested the feasibility of using several types of animal sera as a replacement for individual human sera. An immunoassay without the blank test was developed using Ro(+)-E. coli by (1) blocking with rabbit serum, and (2) cleaving the Fc region from antibodies using papain. Modified E. coli with autodisplayed Ro protein was immobilized to a surface-modified microplate and the applicability of the immunoassay without the blank test was demonstrated using sera from patients with systemic lupus erythematosus (SLE). Using this approach, a microarray-based fluorescence immunoassay with immobilized Ro(+)-E. coli was able to detect anti-Ro autoantibodies in SLE patient sera with high specificity and selectivity and improved efficiency.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Autodisplay; Autoimmune; Fluorescence immunoassay; Microarray; Ro-protein; Systemic lupus erythematosus (SLE)

Mesh:

Substances:

Year:  2014        PMID: 24583694     DOI: 10.1016/j.bios.2014.02.018

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  Lysozyme aptasensor based on a glassy carbon electrode modified with a nanocomposite consisting of multi-walled carbon nanotubes, poly(diallyl dimethyl ammonium chloride) and carbon quantum dots.

Authors:  Behzad Rezaei; Hamid Reza Jamei; Ali Asghar Ensafi
Journal:  Mikrochim Acta       Date:  2018-02-14       Impact factor: 5.833

Review 2.  Chemical Sensors Based on Two-Dimensional (2D) Materials for Selective Detection of Ions and Molecules in Liquid.

Authors:  Chung Won Lee; Jun Min Suh; Ho Won Jang
Journal:  Front Chem       Date:  2019-11-15       Impact factor: 5.221

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.