PURPOSE: To describe the transvenous application of intracardiac echocardiography (ICE) for guidance during endovascular aortic repair (EVAR).
MATERIALS AND METHODS: Eight patients with an infrarenal abdominal aortic aneurysm (AAA) and chronic renal failure were determined suitable for EVAR. The procedure was performed by deploying the transcaval and transiliac vein guidance of an ICE catheter to reduce the dosage of iodinated contrast medium. Multiple guidance parameters were assessed. The present study describes the EVAR procedure and postprocedure transabdominal ultrasound (US) follow-up results at 3-4 months.
RESULTS: The eight procedures were completed by using transvenous ICE guidance. No contrast medium was used in five patients, and 3-20 mL of isoosmolar contrast medium was administered in the other three. No endoleaks were detected by ICE immediately after stent deployment. One patient who had a single functioning kidney developed renal failure that was attributed to manipulation-related cholesterol embolization. That patient became dependent on dialysis and died 3.5 months after the procedure. No endoleaks were detected at 3-4-month US follow-up in the other seven patients.
CONCLUSIONS: Transvenous ICE guidance is a promising method to reduce the dosage of iodinated contrast medium in patients with renal dysfunction undergoing EVAR. A prospective trial comparing this modality versus digital subtraction angiography guidance with iodinated contrast medium in terms of safety, accuracy, and long-term efficacy is recommended.
Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24582172     DOI: 10.1016/j.jvir.2013.12.561

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  1 in total

1.  Clinical outcomes of endovascular aneurysm repair of abdominal aortic aneurysm complicated with hypertension: A 5-year experience.

Authors:  Xi-Tao Peng; Qi-Dong Yuan; Ming-Zhe Cui; Hong-Chao Fang
Journal:  Pak J Med Sci       Date:  2016 Jan-Feb       Impact factor: 1.088

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.