Literature DB >> 24582042

Coronary stent evaluation with coronary computed tomographic angiography: comparison between low-osmolar, high-iodine concentration iomeprol-400 and iso-osmolar, lower-iodine concentration iodixanol-320.

Daniele Andreini1, Gianluca Pontone2, Saima Mushtaq2, Antonio L Bartorelli3, Edoardo Conte2, Erika Bertella2, Andrea Baggiano2, Andrea Annoni2, Alberto Formenti2, Giovanni Ballerini2, Piergiuseppe Agostoni3, Cesare Fiorentini3, Mauro Pepi2.   

Abstract

BACKGROUND: Reliability of coronary angiography by multidetector row CT (MDCT-CA) for stent evaluation is still a matter for debate, and it is unknown whether contrast medium characteristics may affect diagnostic performance of MDCT-CA.
OBJECTIVE: We compared iomeprol-400 with iodixanol-320 to evaluate coronary stents with MDCT-CA.
METHODS: We randomly assigned 254 patients undergoing coronary stent follow-up with the use of MDCT-CA to iomeprol-400 at 5.0 mL/sec flow rate (group 1; n = 83), iodixanol-320 at 6.2 mL/sec flow rate (group 2; n = 87), and iodixanol-320 at 5.0 mL/sec flow rate (group 3; n = 84). Heart rate (HR) immediately before and at the end of scanning, HR variation, premature heart beats, and heat sensation by visual analog scale during scanning were recorded. Mean attenuation was measured in the aortic root and coronary arteries. Image quality score and type of artifacts were assessed.
RESULTS: Mean attenuation was significantly lower in group 3 than in the other groups. In group 3, stent evaluability was significantly higher and artifact rate was significantly lower than in group 2 (99% vs. 91% and 4% vs. 15%) and group 1 (99% vs. 92% and 4% vs. 17%), respectively, mainly because of a significant lower rate of beam-hardening artifacts (3 cases in group 3 vs. 22 and 27 in groups 2 and 3, respectively). In group 3, visual analog scale, HR at the end of imaging, and number of patients with premature heart beats during the scan were significantly lower than in the other groups.
CONCLUSIONS: Iodixanol-320 provides better image quality of coronary stents, allowing higher MDCT-CA evaluability, than iomeprol-400.
Copyright © 2014 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Coronary stent; Iso-osmolar low-iodine concentration contrast medium; Multidetector computed tomography coronary angiography

Mesh:

Substances:

Year:  2014        PMID: 24582042     DOI: 10.1016/j.jcct.2013.12.003

Source DB:  PubMed          Journal:  J Cardiovasc Comput Tomogr        ISSN: 1876-861X


  4 in total

1.  Stent evaluation by coronary computed tomography angiography: a comparison between Iopamidol-370 and Ioversol-320 hypo-osmolar iodine concentration contrasts.

Authors:  Annelisa Moura Garcia; Antonildes N Assunção-Jr; Roberto Nery Dantas-Jr; Jose Rodrigues Parga; Fernando Ganem
Journal:  Br J Radiol       Date:  2020-08-20       Impact factor: 3.039

2.  Diagnostic Phase of Calcium Scoring Scan Applied as the Center of Acquisition Window of Coronary Computed Tomography Angiography Improves Image Quality in Minimal Acquisition Window Scan (Target CTA Mode) Using the Second Generation 320-Row CT.

Authors:  Eriko Maeda; Kodai Yamamoto; Shigeaki Kanno; Kenji Ino; Nobuo Tomizawa; Masaaki Akahane; Rumiko Torigoe; Kuni Ohtomo
Journal:  ScientificWorldJournal       Date:  2016-02-10

Review 3.  Low radiation dose in computed tomography: the role of iodine.

Authors:  Andrik J Aschoff; Carlo Catalano; Miles A Kirchin; Martin Krix; Thomas Albrecht
Journal:  Br J Radiol       Date:  2017-05-04       Impact factor: 3.039

4.  [Comparative Analysis of Image Quality and Adverse Events between Iopamidol 250 and Ioversol 320 in Hepatic Angiography for Transcatheter Arterial Chemoembolization].

Authors:  Min Jae Gu; Jae Hyuck Yi; Young Hwan Kim; Hee Jung Lee; Ung Rae Kang; Seung Woo Ji
Journal:  Taehan Yongsang Uihakhoe Chi       Date:  2020-01-31
  4 in total