Literature DB >> 24581210

Miniscrew implant applications in contemporary orthodontics.

Hong-Po Chang1, Yu-Chuan Tseng2.   

Abstract

The need for orthodontic treatment modalities that provide maximal anchorage control but with minimal patient compliance requirements has led to the development of implant-assisted orthodontics and dentofacial orthopedics. Skeletal anchorage with miniscrew implants has no patient compliance requirements and has been widely incorporated in orthodontic practice. Miniscrew implants are now routinely used as anchorage devices in orthodontic treatment. This review summarizes recent data regarding the interpretation of bone data (i.e., bone quantity and quality) obtained by preoperative diagnostic computed tomography (CT) or by cone-beam computed tomography (CBCT) prior to miniscrew implant placement. Such data are essential when selecting appropriate sites for miniscrew implant placement. Bone characteristics that are indications and contraindications for treatment with miniscrew implants are discussed. Additionally, bicortical orthodontic skeletal anchorage, risks associated with miniscrew implant failure, and miniscrew implants for nonsurgical correction of occlusal cant or vertical excess are reviewed. Finally, implant stability is compared between titanium alloy and stainless steel miniscrew implants.
Copyright © 2013. Published by Elsevier B.V.

Entities:  

Keywords:  Miniscrew implants; Orthodontic anchorage; Risk factors

Mesh:

Substances:

Year:  2013        PMID: 24581210     DOI: 10.1016/j.kjms.2013.11.002

Source DB:  PubMed          Journal:  Kaohsiung J Med Sci        ISSN: 1607-551X            Impact factor:   2.744


  8 in total

Review 1.  Effect of photobiomodulation therapy on mini-implant stability: a systematic review and meta-analysis.

Authors:  Bo Zhang; Xinqi Huang; Sibei Huo; Chenghao Zhang; Xiao Cen; Zhihe Zhao
Journal:  Lasers Med Sci       Date:  2021-03-04       Impact factor: 3.161

2.  Effect of thread depth and thread pitch on the primary stability of miniscrews receiving a torque load : A finite element analysis.

Authors:  Yushan Ye; Weimin Yi; Song Fan; Luodan Zhao; Yansong Yu; Yingjuan Lu; Qinghe Yao; Wei Wang; Shaohai Chang
Journal:  J Orofac Orthop       Date:  2021-09-28       Impact factor: 1.938

3.  Optimization Analysis of Two-Factor Continuous Variable between Thread Depth and Pitch of Microimplant under Toque Force.

Authors:  Yushan Ye; Jiuyang Jiao; Song Fan; Jieying He; Yamei Wang; Qinghe Yao; Wei Wang; Jinsong Li; Shaohai Chang
Journal:  Comput Math Methods Med       Date:  2022-06-20       Impact factor: 2.809

4.  Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants.

Authors:  Celha Borges Costa Alves; Márcio Nunes Segurado; Miriam Cristina Leandro Dorta; Fátima Ribeiro Dias; Maurício Guilherme Lenza; Marcos Augusto Lenza
Journal:  Dental Press J Orthod       Date:  2016 Sep-Oct

5.  Safe regions of miniscrew implantation for distalization of mandibular dentition with CBCT.

Authors:  Haibo Liu; Xiaoxue Wu; Jun Tan; Xiao Li
Journal:  Prog Orthod       Date:  2019-12-09       Impact factor: 2.750

6.  Optimal Implantation Site of Orthodontic Micro-Screws in the Mandibular Anterior Region Based on CBCT.

Authors:  Yannan Wang; Quan Shi; Feng Wang
Journal:  Front Physiol       Date:  2021-05-20       Impact factor: 4.566

7.  Evaluation of mini-implant sites in the posterior maxilla using traditional radiographs and cone-beam computed tomography.

Authors:  Mona A Abbassy; Hanady M Sabban; Ali H Hassan; Khalid H Zawawi
Journal:  Saudi Med J       Date:  2015-11       Impact factor: 1.484

8.  Anatomical consideration for optimal position of orthodontic miniscrews in the maxilla: a CBCT appraisal.

Authors:  Maha S Al Amri; Hanadi M Sabban; Doaa H Alsaggaf; Fahad F Alsulaimani; Ghassan A Al-Turki; Mohammad S Al-Zahrani; Khalid H Zawawi
Journal:  Ann Saudi Med       Date:  2020-08-06       Impact factor: 1.526

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.