Abstract
We herein describe a unique case of coronary artery perforation treated with covered stent with repeat cardiac tamponade resulting out of a fresh unexplained leak from a remote vessel (Ricochet) and successfully treated with intra-coronary injection of sterile synthetic glue, cyanoacrylate.Entities:
Keywords: Angioplasty; Electrocardiogram; ISR; Intra-arterial glue; PTCA
Mesh:
Substances:
Year: 2013 PMID: 24581110 PMCID: PMC4054828 DOI: 10.1016/j.ihj.2013.12.031
Source DB: PubMed Journal: Indian Heart J ISSN: 0019-4832
Fig. 1Diagnostic angiograms showing severe in-stent restenosis in Major OM stent.
Fig. 2A- Slight bulge in contour (black arrow) seen at distal end of stent post dilatation. B- Progression to Ellis grade III perforation.
Fig. 3A- Covered stent Graft-master 3 × 16 mm deployed. B- No residual leak from perforation site.
Fig. 4Check angiogram showing jet of contrast from tip of ramus (Black arrow) and no leak from covered stent site (white arrow).