Literature DB >> 24580851

Multivariate curve resolution based chromatographic peak alignment combined with parallel factor analysis to exploit second-order advantage in complex chromatographic measurements.

Hadi Parastar1, Nadia Akvan2.   

Abstract

In the present contribution, a new combination of multivariate curve resolution-correlation optimized warping (MCR-COW) with trilinear parallel factor analysis (PARAFAC) is developed to exploit second-order advantage in complex chromatographic measurements. In MCR-COW, the complexity of the chromatographic data is reduced by arranging the data in a column-wise augmented matrix, analyzing using MCR bilinear model and aligning the resolved elution profiles using COW in a component-wise manner. The aligned chromatographic data is then decomposed using trilinear model of PARAFAC in order to exploit pure chromatographic and spectroscopic information. The performance of this strategy is evaluated using simulated and real high-performance liquid chromatography-diode array detection (HPLC-DAD) datasets. The obtained results showed that the MCR-COW can efficiently correct elution time shifts of target compounds that are completely overlapped by coeluted interferences in complex chromatographic data. In addition, the PARAFAC analysis of aligned chromatographic data has the advantage of unique decomposition of overlapped chromatographic peaks to identify and quantify the target compounds in the presence of interferences. Finally, to confirm the reliability of the proposed strategy, the performance of the MCR-COW-PARAFAC is compared with the frequently used methods of PARAFAC, COW-PARAFAC, multivariate curve resolution-alternating least squares (MCR-ALS), and MCR-COW-MCR. In general, in most of the cases the MCR-COW-PARAFAC showed an improvement in terms of lack of fit (LOF), relative error (RE) and spectral correlation coefficients in comparison to the PARAFAC, COW-PARAFAC, MCR-ALS and MCR-COW-MCR results.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chromatography; Correlation optimized warping; Multivariate curve resolution; Parallel factor analysis; Second-order advantage

Year:  2014        PMID: 24580851     DOI: 10.1016/j.aca.2014.01.051

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

Review 1.  Recent applications of chemometrics in one- and two-dimensional chromatography.

Authors:  Tijmen S Bos; Wouter C Knol; Stef R A Molenaar; Leon E Niezen; Peter J Schoenmakers; Govert W Somsen; Bob W J Pirok
Journal:  J Sep Sci       Date:  2020-03-19       Impact factor: 3.645

2.  Chemometric evaluation of Saccharomyces cerevisiae metabolic profiles using LC-MS.

Authors:  Mireia Farrés; Benjamí Piña; Romà Tauler
Journal:  Metabolomics       Date:  2014-06-25       Impact factor: 4.290

3.  Interference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods.

Authors:  Shiva Ghafghazi; Taraneh Moini Zanjani; Maryam Vosough; Masoumeh Sabetkasaei
Journal:  Iran J Pharm Res       Date:  2017       Impact factor: 1.696

4.  Automatic time-shift alignment method for chromatographic data analysis.

Authors:  Qing-Xia Zheng; Hai-Yan Fu; He-Dong Li; Bing Wang; Cui-Hua Peng; Sheng Wang; Jun-Lan Cai; Shao-Feng Liu; Xiao-Bing Zhang; Yong-Jie Yu
Journal:  Sci Rep       Date:  2017-03-21       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.