Literature DB >> 24579877

Load sharing in lumbar spinal segment as a function of location of center of rotation.

Yunus Alapan1, Semih Sezer, Cihan Demir, Tuncay Kaner, Serkan İnceoğlu.   

Abstract

OBJECT: The center (axis) of rotation (COR) in the lumbar spine has been studied well. However, there is limited information on the kinetic and kinematic consequences of imposed shift in the location of the COR, although this type of shift can be seen after surgeries using motion preservation or dynamic stabilization devices. The objective of this study was to assess the kinetic and kinematic changes in the lumbar spinal segment due to various imposed CORs.
METHODS: A 3D finite element model of the L4-5 segment was constructed and validated. The segment was loaded under a 7.5-Nm bending moment while constrained to rotate about various imposed CORs in the sagittal and axial motion planes. Range of motion, ligament forces, facet loads, and disc stresses were measured.
RESULTS: The present model showed an agreement with previous in vitro and finite element studies under the same load and boundary conditions. Range of motion, facet forces, disc stresses, and ligament loads showed a strong association with the location of the COR.
CONCLUSIONS: Acute alterations in the location of the COR can significantly change the load sharing characteristics within the spine segment. The normal location of the COR is a result of the tendency of the vertebra to move in the path of least cumulative resistance.

Mesh:

Year:  2014        PMID: 24579877     DOI: 10.3171/2014.1.SPINE13426

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  3 in total

1.  The role of the facet capsular ligament in providing spinal stability.

Authors:  Emily A Bermel; Victor H Barocas; Arin M Ellingson
Journal:  Comput Methods Biomech Biomed Engin       Date:  2018-10       Impact factor: 1.763

2.  Prediction of the Spinal Musculoskeletal Loadings during Level Walking and Stair Climbing after Two Types of Simulated Interventions in Patients with Lumbar Disc Herniation.

Authors:  Shengzheng Kuai; Xinyu Guan; Weiqiang Liu; Run Ji; Jianyi Xiong; Daping Wang; Wenyu Zhou
Journal:  J Healthc Eng       Date:  2019-12-17       Impact factor: 2.682

3.  Effect of the In Situ Screw Implantation Region and Angle on the Stability of Lateral Lumbar Interbody Fusion: A Finite Element Study.

Authors:  Guangye Zhu; Zhihua Wu; Zhichao Fang; Peng Zhang; Jiahui He; Xiang Yu; Zhilin Ge; Kai Tang; Xiaobing Jiang; Ziyang Liang; Jianchao Cui
Journal:  Orthop Surg       Date:  2022-06-03       Impact factor: 2.279

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.