How frequent is rotational mismatch within 0°±10° in kinematically aligned total knee arthroplasty?

Alexander J Nedopil, Stephen M Howell, Maximilian Rudert, Josh Roth, Maury L Hull.   

Abstract

Rotational mismatch of the tibial component on the femoral component within 0°±10° is associated with better function after mechanically aligned total knee arthroplasty (TKA). Kinematically aligned TKA has gained interest; however, the percentage of kinematically aligned TKA within 0°±10° is unknown. The authors prospectively followed all patients who underwent TKA for primary osteoarthritis between December 2011 and April 2012 (194 patients, 195 knees). Each underwent kinematically aligned TKA with manual instruments. Aligning the anteroposterior axis of the tibial component parallel to the line that bisects the oval boundary of the lateral tibial condyle set internal/external rotation. Removing bone from the posterior femoral condyles equal in thickness to the femoral component after correction for cartilage wear set internal/external rotation and anteroposterior translation of the femoral component. Rotational mismatch of the tibial component on the femoral component was determined from a computed tomography scan of the knee. Ninety-seven percent of kinematically aligned TKA with fixed-bearing components had a rotational mismatch within 0°±10° (overall range, -11° to 11°). This percentage was higher and the range narrower than the 85% of TKA within 0°±10° and the -14° to 16° range reported for mechanically aligned TKA. The use of manual instruments to kinematically aligned TKA reliably limited rotational mismatch to within 0°±10°, which has been associated with better function.

Entities:  

Mesh:

Year:  2013        PMID: 24579223     DOI: 10.3928/01477447-20131120-15

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  5 in total

Review 1.  [Kinematic alignment in total knee arthroplasty : Concept, evidence base and limitations].

Authors:  T Calliess; M Ettinger; C Stukenborg-Colsmann; H Windhagen
Journal:  Orthopade       Date:  2015-04       Impact factor: 1.087

2.  What mechanisms are associated with tibial component failure after kinematically-aligned total knee arthroplasty?

Authors:  Alexander J Nedopil; Stephen M Howell; Maury L Hull
Journal:  Int Orthop       Date:  2017-05-11       Impact factor: 3.075

3.  What clinical characteristics and radiographic parameters are associated with patellofemoral instability after kinematically aligned total knee arthroplasty?

Authors:  Alexander J Nedopil; Stephen M Howell; Maury L Hull
Journal:  Int Orthop       Date:  2016-09-12       Impact factor: 3.075

4.  Accurate alignment and high function after kinematically aligned TKA performed with generic instruments.

Authors:  Stephen M Howell; Stelios Papadopoulos; Kyle T Kuznik; Maury L Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-15       Impact factor: 4.342

5.  Three-dimensional analysis of the tibial resection plane relative to the arthritic tibial plateau in total knee arthroplasty.

Authors:  J Michael Johnson; Mohamed R Mahfouz; Mehmet Rüştü Midillioğlu; Alexander J Nedopil; Stephen M Howell
Journal:  J Exp Orthop       Date:  2017-08-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.