Literature DB >> 24576767

Development of a sensitive LC/MS/MS method for vitamin D metabolites: 1,25 Dihydroxyvitamin D2&3 measurement using a novel derivatization agent.

Curtis J Hedman1, Donald A Wiebe2, Subhakar Dey3, Josh Plath3, Joseph W Kemnitz4, Toni E Ziegler5.   

Abstract

Active vitamin D metabolites 1,25-dihydroxyvitamin D2 [1,25-(OH)2-D2; derived from ergocalciferol] and D3 [1,25-(OH)2-D3; derived from cholecalciferol] are found in low levels in the circulation and require a very sensitive method for measurement. Radioimmunoassay (RIA) has been the method of choice, but it lacks the specificity needed to distinguish between 1,25-(OH)2-D2 and -D3, whereas liquid chromatography-tandem mass spectrometry (LC/MS/MS) methods have the advantage of high specificity and sensitivity. Here, we compare a new derivative for ionizing 1,25-(OH)2-D to enhance the signal and provide the most sensitive assay for measuring vitamin D. We used the Amplifex diene method of derivatizing prior to LC/MS/MS and compared it to the standard RIA method and the 4-phenyl-1,2,4-triazole-3,5-dione (PTAD) method of derivatizing prior to LC/MS/MS. In the evaluation of 20 human serum samples, all methods correlated strongly across the upper levels of the standard 1,25-(OH)2-D2 and -D3 ranges (Amplifex and RIA, pc=0.97; Amplifex and PTAD, pc=0.96) but less strongly on the lower levels of the standard range (Amplifex and RIA, pc=0.81; Amplifex and PTAD, pc=0.65) suggesting differences in the sensitivities between the assays. The Amplifex method was determined to be more sensitive than the PTAD method, as peak areas were significantly higher for the Amplifex method and provided for a 10 fold higher signal-to-noise ratio than PTAD. Therefore, the Amplifex LC/MS/MS method is the most sensitive and specific method available for measuring 1,25-(OH)2-D2 and -D3 while using the smallest sample volume.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  1,25 Dihydroxyvitamin D; Derivatization method; Liquid chromatography; Tandem mass spectrometry

Mesh:

Substances:

Year:  2014        PMID: 24576767      PMCID: PMC4050665          DOI: 10.1016/j.jchromb.2014.01.045

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  6 in total

1.  Metabolic profiling of major vitamin D metabolites using Diels-Alder derivatization and ultra-performance liquid chromatography-tandem mass spectrometry.

Authors:  Pavel A Aronov; Laura M Hall; Katja Dettmer; Charles B Stephensen; Bruce D Hammock
Journal:  Anal Bioanal Chem       Date:  2008-04-24       Impact factor: 4.142

Review 2.  Advances in determination of vitamin D related compounds in biological samples using liquid chromatography-mass spectrometry: a review.

Authors:  Tatsuya Higashi; Kazutake Shimada; Toshimasa Toyo'oka
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2009-11-18       Impact factor: 3.205

3.  Sensitive measurement of serum 1α,25-dihydroxyvitamin D by liquid chromatography/tandem mass spectrometry after removing interference with immunoaffinity extraction.

Authors:  Chao Yuan; Justin Kosewick; Xiang He; Marta Kozak; Sihe Wang
Journal:  Rapid Commun Mass Spectrom       Date:  2011-05-15       Impact factor: 2.419

4.  A tribute to Elmer V. McCollum.

Authors:  L E Holt
Journal:  Am J Clin Nutr       Date:  1968-10       Impact factor: 7.045

5.  Quantification of 1α,25-dihydroxy vitamin D by immunoextraction and liquid chromatography-tandem mass spectrometry.

Authors:  Frederick G Strathmann; Thomas J Laha; Andrew N Hoofnagle
Journal:  Clin Chem       Date:  2011-07-18       Impact factor: 8.327

6.  Increasing liquid chromatography-tandem mass spectrometry throughput by mass tagging: a sample-multiplexed high-throughput assay for 25-hydroxyvitamin D2 and D3.

Authors:  Brian C Netzel; Kendall W Cradic; Eric T Bro; Adam B Girtman; Richard C Cyr; Ravinder J Singh; Stefan K G Grebe
Journal:  Clin Chem       Date:  2011-01-18       Impact factor: 8.327

  6 in total
  20 in total

1.  A new sensitive LC/MS/MS analysis of vitamin D metabolites using a click derivatization reagent, 2-nitrosopyridine.

Authors:  Debin Wan; Jun Yang; Bogdan Barnych; Sung Hee Hwang; Kin Sing Stephen Lee; Yongliang Cui; Jun Niu; Mitchell A Watsky; Bruce D Hammock
Journal:  J Lipid Res       Date:  2017-02-01       Impact factor: 5.922

2.  Comparison of vitamin D metabolites in wild and captive baboons.

Authors:  Toni E Ziegler; Amita Kapoor; Neil C Binkley; Karen S Rice; Jeffrey Rogers; Clifford J Jolly; Jane E Phillips-Conroy
Journal:  Am J Primatol       Date:  2018-12       Impact factor: 2.371

3.  Measurement of 25-hydroxyvitamin D(2&3) and 1,25-dihydroxyvitamin D(2&3) by tandem mass spectrometry: A primate multispecies comparison.

Authors:  Toni E Ziegler; Amita Kapoor; Curtis J Hedman; Neil Binkley; Joseph W Kemnitz
Journal:  Am J Primatol       Date:  2015-04-02       Impact factor: 2.371

4.  Clinical utility of simultaneous quantitation of 25-hydroxyvitamin D and 24,25-dihydroxyvitamin D by LC-MS/MS involving derivatization with DMEQ-TAD.

Authors:  Martin Kaufmann; J Christopher Gallagher; Munro Peacock; Karl-Peter Schlingmann; Martin Konrad; Hector F DeLuca; Rita Sigueiro; Borja Lopez; Antonio Mourino; Miguel Maestro; René St-Arnaud; Joel S Finkelstein; Donald P Cooper; Glenville Jones
Journal:  J Clin Endocrinol Metab       Date:  2014-03-26       Impact factor: 5.958

5.  Cationic Xylene Tag for Increasing Sensitivity in Mass Spectrometry.

Authors:  Poguang Wang; Qi Zhang; Yuanyuan Yao; Roger W Giese
Journal:  J Am Soc Mass Spectrom       Date:  2015-06-27       Impact factor: 3.109

6.  A newly developed and validated LC-MS/MS method for measuring 7-dehydrocholesterol (7DHC) concentration in human skin: a tool for vitamin D photobiology research.

Authors:  Oktawia Borecka; Lesley E Rhodes; Ann R Webb; John J Dutton; William D Fraser
Journal:  Photochem Photobiol Sci       Date:  2022-07-29       Impact factor: 4.328

7.  Selective identification of specialized pro-resolving lipid mediators from their biosynthetic double di-oxygenation isomers.

Authors:  Trond V Hansen; Jesmond Dalli; Charles N Serhan
Journal:  RSC Adv       Date:  2016-03-04       Impact factor: 3.361

8.  Utilizing cooled liquid chromatography and chemical derivatization to separate and quantify C3-epimers of 25-hydroxy vitamin D and low abundant 1α,25(OH)2D3: Application in a pediatric population.

Authors:  Brian C DeFelice; Theresa L Pedersen; Hanan Shorrosh; Randi K Johnson; Jennifer A Seifert; Jill M Norris; Oliver Fiehn
Journal:  J Steroid Biochem Mol Biol       Date:  2019-11-10       Impact factor: 4.292

9.  Rapid Quantification of 25-Hydroxyvitamin D3 in Human Serum by Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry.

Authors:  Yulin Qi; Miriam Müller; Caroline S Stokes; Dietrich A Volmer
Journal:  J Am Soc Mass Spectrom       Date:  2018-04-09       Impact factor: 3.109

10.  Chemotyping the distribution of vitamin D metabolites in human serum.

Authors:  Miriam J Müller; Caroline S Stokes; Frank Lammert; Dietrich A Volmer
Journal:  Sci Rep       Date:  2016-02-11       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.