Literature DB >> 24571886

Safety and efficacy of bimatoprost/timolol fixed combination in Chinese patients with open-angle glaucoma or ocular hypertension.

Zhihong Ling1, Mingchang Zhang2, Yizhen Hu2, Zhengqin Yin3, Yiqiao Xing4, Aiwu Fang5, Jian Ye6, Xiaoming Chen7, Dachuan Liu8, Yusheng Wang9, Wei Sun10, Yangceng Dong11, Xinghuai Sun12.   

Abstract

BACKGROUND: Lowering intraocular pressure (IOP) is currently the only therapeutic approach in primary open-angle glaucoma. and the fixed-combination medications are needed to achieve sufficiently low target IOP. A multicenter prospective study in the Chinese population was needed to confirm the safety and efficacy of Bimatoprost/Timolol Fixed Combination Eye Drop in China. In this study, we evaluated the safety and efficacy of Bimatoprost/Timolol Fixed Combination with concurrent administration of its components in Chinese patients with open-angle glaucoma or ocular hypertension.
METHODS: In this multicenter, randomized, double-masked, parallel controlled study, patients with open-angle glaucoma or ocular hypertension who were insufficiently responsive to monotherapy with either topical β-blockers or prostaglandin analogues were randomized to one of two active treatment groups in a 1:1 ratio at 11 Chinese ophthalmic departments. Bimatoprost/timolol fixed combination treatment was a fixed combination of 0.03% bimatoprost and 0.5% timolol (followed by vehicle for masking) once daily at 19:00 P.M. and concurrent treatment was 0.03% bimatoprost followed by 0.5% timolol once daily at 19:00 P.M. The primary efficacy variable was change from baseline in mean diurnal intraocular pressure (IOP) at week 4 visit in the intent-to-treat (ITT) population. Primary analysis evaluated the non-inferiority of bimatoprost/ timolol fixed combination to concurrent with respect to the primary variable using a confidence interval (CI) approach. Bimatoprost/timolol fixed combination was to be considered non-inferior to concurrent if the upper limit of the 95% CI for the between-treatment (bimatoprost/timolol fixed combination minus concurrent) difference was ≤ 1.5 mmHg. Adverse events were collected and slit-lamp examinations were performed to assess safety. Between-group comparisons of the incidence of adverse events were performed using the Pearson chi-square test or Fisher's exact test.
RESULTS: Of the enrolled 235 patients, 121 patients were randomized to receive bimatoprost/timolol fixed combination and, 114 patients were randomized to receive concurrent treatment. At baseline the mean value of mean diurnal IOP was (25.20 ± 3.06) mmHg in the bimatoprost/timolol fixed combination group and (24.87 ± 3.88) mmHg in the concurrent group. The difference between the treatment groups was not statistically significant. The mean change from baseline in mean diurnal IOP (± standard deviation) in the bimatoprost/timolol fixed combination group was (-9.38 ± 4.66) mmHg and it was (-8.93 ± 4.25) mmHg in the concurrent group (P < 0.01). The difference between the two treatment groups (bimatoprost/timolol fixed combination minus concurrent) in the change from baseline of mean diurnal IOP was -0.556 mmHg (95% CI: -1.68, 0.57, P = 0.330). The upper limit of the 95% CI was less than 1.5 mmHg, the predefined margin of non-inferiority. Adverse events occurred in 26.4% (32/121) of the bimatoprost/timolol fixed combination patients and 30.7% (35/114) of the concurrent patients. The most frequent adverse event was conjunctival hyperemia, which was reported as treatment related in 16.5% (20/121) in the bimatoprost/timolol fixed combination group and 18.4% (21/114) in the concurrent group (P > 0.05).
CONCLUSIONS: Bimatoprost/Timolol Fixed Combination administered in Chinese patients with open-angle glaucoma or ocular hypertension was not inferior to concurrent dosing with the individual components. Safety profiles were similar between the treatment groups.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24571886

Source DB:  PubMed          Journal:  Chin Med J (Engl)        ISSN: 0366-6999            Impact factor:   2.628


  4 in total

Review 1.  Fixed-combination treatments for intraocular hypertension in Chinese patients - focus on bimatoprost-timolol.

Authors:  Yuan Fang; Zhihong Ling; Xinghuai Sun
Journal:  Drug Des Devel Ther       Date:  2015-05-13       Impact factor: 4.162

Review 2.  Fixed-dose combination of tafluprost and timolol in the treatment of open-angle glaucoma and ocular hypertension: comparison with other fixed-combination products.

Authors:  Gábor Holló; Jouni Vuorinen; Juhani Tuominen; Teppo Huttunen; Auli Ropo; Norbert Pfeiffer
Journal:  Adv Ther       Date:  2014-09-12       Impact factor: 3.845

3.  Patient satisfaction with fixed-combination bimatoprost/timolol ophthalmic solution: a survey study in patients with glaucoma in China.

Authors:  Xinghuai Sun; Mingkai Lin; Xuanchu Duan; Chun Zhang; Jian Ming
Journal:  Patient Prefer Adherence       Date:  2017-04-28       Impact factor: 2.711

4.  Prospective, non-interventional, multicenter study of the intraocular pressure-lowering effects of prostaglandin analog/prostamide-containing therapies in previously treated patients with open-angle glaucoma or ocular hypertension.

Authors:  Nevbahar Tamçelik; Belgin Izgi; Ahmet Temel; Nilgun Yildirim; Mehmet Okka; Altan Özcan; Nurşen Yüksel; Ufuk Elgin; Çiğdem Altan; Baris Ozer
Journal:  Clin Ophthalmol       Date:  2017-04-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.