BACKGROUND: Rapid diagnostic tests (RDTs) are the current complement to microscopy for ensuring prompt malaria treatment. We determined the performance of three candidate RDTs (Paracheck™-Pf, SD Bioline malaria Ag-Pf and SD Bioline malaria Ag-Pf/pan) for rapid diagnosis of malaria in the Central African Republic.Entities:
Mesh:
Year: 2014 PMID: 24568311 PMCID: PMC3938899 DOI: 10.1186/1471-2334-14-109
Source DB: PubMed Journal: BMC Infect Dis ISSN: 1471-2334 Impact factor: 3.090
Figure 1Rapid diagnostic test performance results by parasitaemia level.
Sensitivity of rapid diagnostic tests by parasite density (microscopy)
| ≤ 100 | 23 | 69.6 | [47.1–86.8] | 69.6 | [50.8– 88.4] | 56.5 | [34.5–76.8] |
| 101–200 | 41 | 80.5 | [65.1–91.2] | 80.9 | [68.9– 92.9] | 63.4 | [46.9–77.9] |
| 201–500 | 28 | 89.3 | [71.8–97.7] | 89.3 | [71.8–97.7] | 82.1 | [63.1–93.9] |
| 501–1000 | 40 | 100 | – | 100 | – | 100 | – |
| 1001–5000 | 34 | 97.1 | [85.1–99.9] | 100 | – | 91.2 | [76.3–98.1] |
| 5001–50 000 | 58 | 100 | – | 100 | – | 98.3 | [90.8–99.9] |
| > 50 000 | 11 | 100 | – | 100 | – | 100 | – |
Overall sensitivity, specificity and negative and positive predictive value of the three RDTs evaluated against microscopy, and microscopy and PCR
| | |||||
|---|---|---|---|---|---|
| Microscopy | 85.9 [80.8-90.1] | 86.6 [81.1-91.0] | 88.2 [83.2-92.1] | 84.1 [78.4-88.8] | |
| Microscopy and PCR | 85.7 [80.8–89.8] | 86.0 [80.1–90.6] | 89.3 [84.7-92.9] | 81.5 [75.4-86.7] | |
| Microscopy | 92.3 [88.1-95.4] | 82.2 [76.2-87.2] | 85.7 [80.8-89.8] | 90.2 [85.0-94.1] | |
| Microscopy and PCR | 85.4 [80.5–90.7] | 86.3 [80.5–9.7] | 89.7 [85.1-93.2] | 81.0 [74.8-86.3] | |
| Microscopy | 92.3 [88.1-95.4] | 81.2 [81.1-91.0] | 85.0 [80.0-89.2] | 90.1 [84.8-94.0] | |
| Microscopy and PCR | 88.2 [83.2–92.0%] | 80.4 [74.3–85.5] | 83.1 [77.7-87.6] | 86.1 [80.5-90.7] |