Literature DB >> 24568172

Microleakage and microtensile bond strength of silorane-based and dimethacrylate-based restorative systems.

Maria Jacinta Moraes Coelho Santos1, Aaron Podorieszach2, Amin Sami Rizkalla3, Gildo Coelho Santos4.   

Abstract

OBJECTIVE: To evaluate the microleakage and bond strengths (microTBS) of silorane-based (SBC) and dimethacrylate-based (DBC) restorative systems. The null hypotheses are: 1) there is no difference in microleakage between the resin composites and the adhesive systems tested at the enamel and dentin margins; 2) there is no significant difference in microTBS between the composite restorative systems using self-etch and etch-and-rinse adhesive versions. METHODS AND MATERIALS: Microleakage: Class V cavity preparations with cervical margin in dentin were performed on pristine extracted human molars and were randomly distributed among the following three groups: Group 1-DBC/etch-and-rinse adhesive system (Filtek™ Supreme Ultra/Adper™ Single Bond Plus, 3M ESPE, www.3MESPE.com); Group 2-SBC/self-etch adhesive (Filtek LS Low Shrink Posterior Restorative System/LS self-etch adhesive, 3M ESPE); Group 3-DBC/self-etch adhesive (Filtek Supreme Ultra/ Adper Easy Bond Self-Etch, 3M ESPE). Restorations were thermocycled and immersed in 0.2 percent methylene blue dye for 24 hours. Samples were assessed visually under 10x magnification; microTBS: Bond sticks (0.9 mm2) were prepared from each group and tested on a universal testing machine.
RESULTS: The Kruskal-Wallis test revealed no significant difference in microleakage among the experimental groups at the enamel margin (P=0.191). At the dentin margins, silorane/self-etch restorative system showed significantly less leakage than the dimethacrylate/etch-and-rinse restorative system (P=0.008). Tukey's B rank order test showed that the dimethacrylate/etch-and-rinse restorative system presented the highest microTBS.
CONCLUSIONS: SBC/self-etch system showed less microleakage at the dentin margins, while DBC/etch-and-rinse system presented higher bond strength.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24568172

Source DB:  PubMed          Journal:  Compend Contin Educ Dent        ISSN: 1548-8578


  2 in total

1.  Comparison of Microtensile Bond Strength of Silorane-Based Composite with the Conventional Methacrylate Composite to the Dentin of Primary Teeth.

Authors:  Sharifi M; Khoramian Tusi S
Journal:  J Dent Biomater       Date:  2016-12

2.  Evaluation of Shear Bond Strength of Methacrylate- and Silorane-based Composite Resin Bonded to Resin-Modified Glass-ionomer Containing Micro- and Nano-hydroxyapatite.

Authors:  Farahnaz Sharafeddin; Marzie Moradian; Mehran Motamedi
Journal:  J Dent (Shiraz)       Date:  2016-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.