Literature DB >> 24567285

Development of a method for the determination of total bisphenol a at trace levels in human blood and urine and elucidation of factors influencing method accuracy and sensitivity.

Dan Markham1, John Waechter, Robert Budinsky, Wolfgang Gries, Dieter Beyer, Stephanie Snyder, Stephen Dimond, V N Rajesh, Narayana Rao, Paul Connolly, Mark Neeley, Steven Hentges.   

Abstract

This publication describes a method for the determination of total bisphenol A (BPA and conjugated BPA) following enzyme hydrolysis and is intended as a companion to our previously developed analytical method for the determination of free BPA (the aglycone) in human blood and urine using high-performance liquid chromatography-tandem mass spectrometry ( 1). That free BPA method provided a means to account for and/or eliminate background contamination and demonstrated accuracy and reproducibility in both matrices fortified with BPA or a surrogate analyte ((13)C BPA) at a low method quantitation limit (MQL) of 0.1-0.2 ng/mL. In contrast to the free BPA method results and based on stringent accuracy, precision and confirmation criteria set for the MQLs of the method developed for total BPA, the MQL achieved in blood was 1.020-2.550 and 0.510-1.020 ng/mL in urine. These data showed higher MQLs than the desired MQLs of 0.5 ng/mL (blood) and 0.2 ng/mL (urine) with increased variability between analyses which demonstrates the importance of generating method validation data with each analysis. In contrast, the MQL achieved for (13)C BPA-G (monoglucuronide as a surrogate analyte in blood was 0.2-0.5 and 0.2 ng/mL in urine illustrating that the method is capable of meeting lower MQL requirements if the contribution from exogenous BPA can be well controlled. This method for the determination total BPA in human blood and urine is intended to be used in conjunction with the free BPA method ( 1) to obtain accurate and complete BPA biomonitoring data to support human exposure assessments.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24567285     DOI: 10.1093/jat/bku012

Source DB:  PubMed          Journal:  J Anal Toxicol        ISSN: 0146-4760            Impact factor:   3.367


  2 in total

1.  Quantification of steroid hormones in low volume plasma and tissue homogenates of fish using LC-MS/MS.

Authors:  Mohammad-Zaman Nouri; Kevin J Kroll; Molly Webb; Nancy D Denslow
Journal:  Gen Comp Endocrinol       Date:  2020-06-27       Impact factor: 2.822

2.  Bisphenol A in edible tissues of rams exposed to repeated low-level dietary dose by high-performance liquid chromatography with fluorescence detection.

Authors:  Vesna Cerkvenik-Flajs; Andrej Škibin; Tanja Švara; Mitja Gombač; Milan Pogačnik; Sabina Šturm
Journal:  Environ Sci Pollut Res Int       Date:  2022-06-05       Impact factor: 5.190

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.