Literature DB >> 24562117

Quantitative Mueller matrix fluorescence spectroscopy for precancer detection.

J Jagtap, S Chandel, N Das, J Soni, S Chatterjee, A Pradhan, N Ghosh.   

Abstract

Quantitative fluorescence spectroscopic Mueller matrix measurements from the connective tissue regions of human cervical tissue reveal intriguing fluorescence diattenuation and polarizance effects. Interestingly, the estimated fluorescence linear diattenuation and polarizance parameters were considerably reduced in the precancerous tissues as compared to the normal ones. These polarimetry effects of the autofluorescence were found to originate from anisotropically organized collagen molecular structures present in the connective tissues. Consequently, the reduction of the magnitude of these polarimetric parameters at higher grades of precancer was attributed to the loss of anisotropic organization of collagen, which was also confirmed by control experiments. These results indicate that fluorescence spectral diattenuation and polarizance parameters may serve as potentially useful diagnostic metrics.

Entities:  

Mesh:

Year:  2014        PMID: 24562117     DOI: 10.1364/OL.39.000243

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  5 in total

1.  Assessment of tissue pathology using optical polarimetry.

Authors:  Zahra Ali; Tariq Mahmood; Ayesha Shahzad; Muaz Iqbal; Iftikhar Ahmad
Journal:  Lasers Med Sci       Date:  2021-10-23       Impact factor: 3.161

2.  Quantitatively characterizing the microstructural features of breast ductal carcinoma tissues in different progression stages by Mueller matrix microscope.

Authors:  Yang Dong; Ji Qi; Honghui He; Chao He; Shaoxiong Liu; Jian Wu; Daniel S Elson; Hui Ma
Journal:  Biomed Opt Express       Date:  2017-07-13       Impact factor: 3.732

3.  Characterizing microstructures of cancerous tissues using multispectral transformed Mueller matrix polarization parameters.

Authors:  Chao He; Honghui He; Jintao Chang; Yang Dong; Shaoxiong Liu; Nan Zeng; Yonghong He; Hui Ma
Journal:  Biomed Opt Express       Date:  2015-07-17       Impact factor: 3.732

4.  Characterizing the Effects of Washing by Different Detergents on the Wavelength-Scale Microstructures of Silk Samples Using Mueller Matrix Polarimetry.

Authors:  Yang Dong; Honghui He; Chao He; Jialing Zhou; Nan Zeng; Hui Ma
Journal:  Int J Mol Sci       Date:  2016-08-10       Impact factor: 5.923

5.  Mueller polarimetric imaging for fast macroscopic mapping of microscopic collagen matrix remodeling by smooth muscle cells.

Authors:  Olga Chashchina; Hachem Mezouar; Jérémy Vizet; Clothilde Raoux; Junha Park; Clara Ramón-Lozano; Marie-Claire Schanne-Klein; Abdul I Barakat; Angelo Pierangelo
Journal:  Sci Rep       Date:  2021-03-15       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.