Literature DB >> 24561562

Microcirculatory alterations in traumatic hemorrhagic shock.

Guillaume Tachon1, Anatole Harrois, Sebastien Tanaka, Hiromi Kato, Olivier Huet, Julien Pottecher, Eric Vicaut, Jacques Duranteau.   

Abstract

OBJECTIVES: Microcirculatory dysfunction has been well reported in clinical studies in septic shock. However, no clinical studies have investigated microcirculatory blood flow behavior in hemorrhagic shock. The main objective of this study was to assess the time course of sublingual microcirculation in traumatic hemorrhagic shock during the first 4 days after trauma.
DESIGN: Prospective observational study. SETTING ICU PATIENTS: Eighteen traumatic hemorrhagic shock patients.
INTERVENTIONS: The sublingual microcirculation was estimated at the study inclusion after surgical or angiographic embolization to control bleeding (D1), and then three times at 24-hour intervals (D2, D3, and D4).
MEASUREMENTS AND MAIN RESULTS: Sublingual microcirculation was impaired for 72 hours despite restoration of the macrovascular circulation after control of bleeding in traumatic hemorrhagic shock patients. Furthermore, we found significantly higher decreases in the microvascular flow index and proportion of perfused vessels in high Sequential Organ Failure Assessment score patients at D4 (Sequential Organ Failure Assessment score ≥ 6) compared to low Sequential Organ Failure Assessment score patients at D4 (Sequential Organ Failure Assessment score < 6) without any differences in global hemodynamics between these two groups. Finally, the initial proportion of perfused vessels at D1 appears to be a good predictor of high Sequential Organ Failure Assessment score at D4.
CONCLUSIONS: Alterations of microcirculation in traumatic hemorrhagic shock patients result from the interplay among hemorrhage-induced tissue hypoperfusion, trauma injuries, inflammatory response, and subsequent resuscitation interventions. Despite restoration of the macrocirculation, the sublingual microcirculation was impaired for at least 72 hours. The initial proportion of perfused vessels appears to be a good predictor of high Sequential Organ Failure Assessment score at D4. Further studies are required to firmly establish the link between microvascular alterations and organ dysfunction in traumatic hemorrhagic shock patients.

Entities:  

Mesh:

Year:  2014        PMID: 24561562     DOI: 10.1097/CCM.0000000000000223

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  50 in total

1.  Venous-to-arterial CO2 differences and the quest for bedside point-of-care monitoring to assess the microcirculation during shock.

Authors:  David N Naumann; Mark J Midwinter; Sam Hutchings
Journal:  Ann Transl Med       Date:  2016-01

2.  Effects of crystalloids and colloids on microcirculation, central venous oxygen saturation, and central venous-to-arterial carbon dioxide gap in a rabbit model of hemorrhagic shock.

Authors:  Makiko Komori; Yuriko Samejima; Keiko Okamura; Junko Ichikawa; Mitsuharu Kodaka; Keiko Nishiyama; Yasuko Tomizawa
Journal:  J Anesth       Date:  2018-12-10       Impact factor: 2.078

Review 3.  [Hypovolemic and hemorrhagic shock].

Authors:  H Lier; M Bernhard; B Hossfeld
Journal:  Anaesthesist       Date:  2018-03       Impact factor: 1.041

4.  Could resuscitation be based on microcirculation data? No.

Authors:  David N Naumann; Alexandre Lima
Journal:  Intensive Care Med       Date:  2018-05-07       Impact factor: 17.440

Review 5.  Microcirculation: Physiology, Pathophysiology, and Clinical Application.

Authors:  Goksel Guven; Matthias P Hilty; Can Ince
Journal:  Blood Purif       Date:  2019-12-18       Impact factor: 2.614

6.  Hemodynamic coherence and the rationale for monitoring the microcirculation.

Authors:  Can Ince
Journal:  Crit Care       Date:  2015-12-18       Impact factor: 9.097

7.  Impact of microcirculatory video quality on the evaluation of sublingual microcirculation in critically ill patients.

Authors:  Elisa Damiani; Can Ince; Claudia Scorcella; Roberta Domizi; Andrea Carsetti; Nicoletta Mininno; Silvia Pierantozzi; Erica Adrario; Rocco Romano; Paolo Pelaia; Abele Donati
Journal:  J Clin Monit Comput       Date:  2016-08-18       Impact factor: 2.502

Review 8.  Alternatives to the Swan-Ganz catheter.

Authors:  Daniel De Backer; Jan Bakker; Maurizio Cecconi; Ludhmila Hajjar; Da Wei Liu; Suzanna Lobo; Xavier Monnet; Andrea Morelli; Sheila Neinan Myatra; Azriel Perel; Michael R Pinsky; Bernd Saugel; Jean-Louis Teboul; Antoine Vieillard-Baron; Jean-Louis Vincent
Journal:  Intensive Care Med       Date:  2018-05-03       Impact factor: 17.440

9.  Diffuse optical monitoring of peripheral tissues during uncontrolled internal hemorrhage in a porcine model.

Authors:  Karthik Vishwanath; Rajan Gurjar; David Wolf; Suzannah Riccardi; Michael Duggan; David King
Journal:  Biomed Opt Express       Date:  2018-01-11       Impact factor: 3.732

10.  In vivo performance of a visible wavelength optical sensor for monitoring intestinal perfusion and oxygenation.

Authors:  Mitchell B Robinson; Anna M Wisniowiecki; Ryan J Butcher; Mark A Wilson; M Nance Ericson; Gerard L Cote
Journal:  J Biomed Opt       Date:  2018-05       Impact factor: 3.170

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.