Literature DB >> 24561115

Validation of rebound tonometry for intraocular pressure measurement in the rabbit.

Hong Zhang1, Dong Yang2, Craig M Ross2, Jonathan P Wigg2, Surinder Pandav3, Jonathan G Crowston2.   

Abstract

Rabbits play a growing role in research into glaucoma surgical models and ocular drug delivery models. However, the lack of an accurate method for measuring intraocular pressure (IOP) in this animal has been a significant deficit. In this study we validated the use of the TonoVet rebound tonometer and provide conversion tables for its use in rabbits. Experiments were performed on 18 adult New Zealand White rabbits. The TonoVet measurements were obtained and compared to manometric readings by anterior chamber (AC) cannulation. The TonoVet position and 'd' (dog or cat) and 'p' (other species) modes were compared. The sensitivity of the TonoVet tonometer in assessing IOP changes was also tested. There was a strong linear correlation for both the 'd' mode (mean slope = 0.84 ± 0.03, r(2) = 0.99 ± 0.03) and the 'p' mode (mean slope = 0.64 ± 0.02, r2 = 0.97 ± 0.01) of the TonoVet with manometric IOP. However, the TonoVet had a tendency to underestimate IOP compared to manometry and conversion formulae were possible to calculate for both modes. The orientation of the TonoVet handle had no effect on IOP reading, as long as the groove was horizontal. No significant differences were observed when comparing right and left eyes (P > 0.05). IOP recovered four days after cannulation. Younger rabbits had lower IOP compared with older rabbits (P < 0.01). Timolol produced a 2.5 mmHg reduction in IOP 2 h later as detected by the TonoVet. Using the conversion table presented, the TonoVet is a reliable and precise tool for the measurement of IOP in rabbits.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  glaucoma; intraocular pressure; non-invasive; rabbits; tonometer

Mesh:

Year:  2014        PMID: 24561115     DOI: 10.1016/j.exer.2014.02.004

Source DB:  PubMed          Journal:  Exp Eye Res        ISSN: 0014-4835            Impact factor:   3.467


  12 in total

1.  Validation of the Icare® TONOVET plus rebound tonometer in normal rabbit eyes.

Authors:  Shawna Gloe; Abby Rothering; Julie A Kiland; Gillian J McLellan
Journal:  Exp Eye Res       Date:  2019-06-12       Impact factor: 3.467

2.  Effects of ripasudil hydrochloride hydrate (K-115), a Rho-kinase inhibitor, on ocular blood flow and ciliary artery smooth muscle contraction in rabbits.

Authors:  Yusuke Ohta; Sanae Takaseki; Takeshi Yoshitomi
Journal:  Jpn J Ophthalmol       Date:  2017-06-26       Impact factor: 2.447

3.  Sustained Delivery of Timolol Maleate for Over 90 Days by Subconjunctival Injection.

Authors:  Erin Lavik; Markus H Kuehn; Andrew J Shoffstall; Kristyn Atkins; Alina V Dumitrescu; Young H Kwon
Journal:  J Ocul Pharmacol Ther       Date:  2016-11-11       Impact factor: 2.671

4.  Effect of Cromakalim Prodrug 1 (CKLP1) on Aqueous Humor Dynamics and Feasibility of Combination Therapy With Existing Ocular Hypotensive Agents.

Authors:  Uttio Roy Chowdhury; Tommy A Rinkoski; Cindy K Bahler; J Cameron Millar; Jacques A Bertrand; Bradley H Holman; Joseph M Sherwood; Darryl R Overby; Kristen L Stoltz; Peter I Dosa; Michael P Fautsch
Journal:  Invest Ophthalmol Vis Sci       Date:  2017-11-01       Impact factor: 4.799

5.  Repeatability, reproducibility and agreement of intraocular pressure measurement in rabbits by the TonoVet and Tono-Pen.

Authors:  Di Ma; Chong-Bo Chen; Jiajian Liang; Zhihao Lu; Haoyu Chen; Mingzhi Zhang
Journal:  Sci Rep       Date:  2016-10-12       Impact factor: 4.379

6.  Comparison of two prototypes of a magnetically adjustable glaucoma implant in rabbits.

Authors:  Birthe Schwerk; Lisa Harder; Claudia Windhövel; Marion Hewicker-Trautwein; Anna Wagner; Jan-Peter Bach; Lena Carolin Voigt; Ulf Hinze; Boris Chichkov; Heinz Haferkamp; Holger Lubatschowski; Stephan Nikolic; Ingo Nolte
Journal:  PLoS One       Date:  2019-04-11       Impact factor: 3.240

7.  Intraocular pressure measurements using the TONOVET® rebound tonometer: Influence of the probe-cornea distance.

Authors:  Blanche D Rodrigues; Fabiano Montiani-Ferreira; Mariza Bortolini; André T Somma; András M Komáromy; Peterson Triches Dornbusch
Journal:  Vet Ophthalmol       Date:  2020-10-17       Impact factor: 1.644

8.  Ocular Hypotensive Effects of the ATP-Sensitive Potassium Channel Opener Cromakalim in Human and Murine Experimental Model Systems.

Authors:  Uttio Roy Chowdhury; Cindy K Bahler; Bradley H Holman; Peter I Dosa; Michael P Fautsch
Journal:  PLoS One       Date:  2015-11-04       Impact factor: 3.240

9.  The influence of the tonometer position on canine intraocular pressure measurements using the Tonovet® rebound tonometer.

Authors:  Juliana Kravetz de Oliveira; Fabiano Montiani-Ferreira; David L Williams
Journal:  Open Vet J       Date:  2018-03-09

10.  Age-Related Variations of Rabbit Corneal Geometrical and Clinical Biomechanical Parameters.

Authors:  Haixia Zhang; Xiao Qin; Xiaomeng Cao; Di Zhang; Lin Li
Journal:  Biomed Res Int       Date:  2017-08-13       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.