Literature DB >> 24559683

SPIDER ® sleeve gastrectomy--a new concept in single-trocar bariatric surgery: initial experience and technical details.

P Noel1, M Nedelcu2, M Gagner3.   

Abstract

INTRODUCTION: Single port instrument delivery extended reach (SPIDER(®)) surgical system is a revolutionary surgical platform that allows triangulation of the surgical instruments while eliminating the crossing of instruments, the problematic characteristic of single access laparoscopic surgery.
METHODS: The purpose of this study was to analyze our initial experience with SPIDER(®) sleeve gastrectomy and to present the technical details of this new minimally invasive approach, performed in ten patients at the La Casamance Private Hospital between November 2012 and April 2013. All patients were reviewed at scheduled post-operative consultations at 1, 3 and 6 months. In addition to clinical examination, the post-operative consultation at one month also included a satisfaction survey using the Moorehead-Ardelt questionnaire.
RESULTS: An initial series of ten sleeve gastrectomies were performed in female patients with a mean age of 41.5 years (range: 2-52). The mean BMI was 40.11 (range: 37.25-44.3). The intervention was performed through a single trocar in all patients with no "conversion" to classic laparoscopy or open surgery. The mean operative time was 61 ± 15.22 minutes (SD=standard deviation) (range: 43-96 min). The mean BMI at one month was 35.5 (SD:± 3.58, SEM: ± 1.13) (SEM=standard error of mean) with an average percentage of excess weight loss (%EWL) of 32.9% (SD:± 8.56%, SEM:± 2.71%). The mean BMI at three months was 32.4 (SD: ± 2.78, SEM: ± 0.88) with an average %EWL of 52.7% (SD: ± 8.64%, SEM: ± 2.73%). The mean BMI at six months was 29.9 (SD:± 2.60, SEM: ± 0.98) with a mean %EWL of 68.8% (SD: ± 8.38%, SEM:± 3.17%). Complete remission of co-morbid conditions was observed in four patients, improvement in three others, and no change in a single patient. The mean duration of hospitalization was 3.1 days. The mean follow-up period was 161 days (SD:± 57.4 days, range: 90-243 days). There was no mortality and no intra-operative and post-operative complications were noted.
CONCLUSIONS: The SPIDER(®) surgical platform seems to be a usable and effective method for performance of minimally invasive single-access sleeve gastrectomy, offering an easy and efficient operative procedure compared to other single-port systems. Prospective long-term studies are recommended before this approach can be validated to be of comparable efficiency to conventional multi-port laparoscopic surgery.
Copyright © 2014 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  SPIDER; Sleeve gastrectomy

Mesh:

Year:  2014        PMID: 24559683     DOI: 10.1016/j.jviscsurg.2014.01.007

Source DB:  PubMed          Journal:  J Visc Surg        ISSN: 1878-7886            Impact factor:   2.043


  8 in total

1.  Reply to the Letter to the Editor Submitted by Michel Gagner (Publish with OBSU-D-15-00482).

Authors:  Scott A Shikora; Christine Brown Mahoney
Journal:  Obes Surg       Date:  2016-01       Impact factor: 4.129

2.  Weight-loss outcomes of SPIDER(®) sleeve gastrectomy at 6 months compared to traditional laparoscopic technique.

Authors:  Kathryn B Muir; William V Rice
Journal:  Surg Endosc       Date:  2015-08-15       Impact factor: 4.584

3.  Laparoscopic cholecystectomy using a novel single-incision surgical platform through a standard 15 mm trocar: initial experience and technical details.

Authors:  Ryan C Broderick; Pablo Omelanczuk; Cristina R Harnsberger; Hans F Fuchs; Martin Berducci; Jorge Nefa; Javier Nicolia; Moneer Almadani; Garth R Jacobsen; Bryan J Sandler; Santiago Horgan
Journal:  Surg Endosc       Date:  2014-08-23       Impact factor: 4.584

4.  European Obesity Summit (EOS) - Joint Congress of EASOand IFSO-EC, Gothenburg, Sweden, June 1 - 4, 2016: Abstracts.

Authors: 
Journal:  Obes Facts       Date:  2016-05-25       Impact factor: 3.942

5.  Phase II clinical experience and long-term follow-up using the next-generation single-incision platform FMX314.

Authors:  Martin Berducci; Hans F Fuchs; Pablo Omelanczuk; Ryan C Broderick; Cristina R Harnsberger; Joshua Langert; Jorge Nefa; Pablo Jaureguiberry; Pablo Gomez; Laura Miranda; Garth R Jacobsen; Bryan J Sandler; Santiago Horgan
Journal:  Surg Endosc       Date:  2015-06-27       Impact factor: 4.584

Review 6.  Single Incision Laparoscopic Sleeve Gastrectomy: a Review.

Authors:  Anastasios Stefanopoulos; Konstantinos P Economopoulos; Vasileios Kalles
Journal:  Obes Surg       Date:  2015-08       Impact factor: 4.129

7.  Single-incision sleeve gastrectomy versus laparoscopic sleeve gastrectomy. A 2-year comparative analysis of 600 patients.

Authors:  Muffazal Lakdawala; Aditi Agarwal; Shilpa Dhar; Neha Dhulla; Carlyne Remedios; Aparna Govil Bhasker
Journal:  Obes Surg       Date:  2015-04       Impact factor: 4.129

8.  Comparison of laparoscopic sleeve gastrectomy leak rates in five staple-line reinforcement options: a systematic review.

Authors:  Michel Gagner; Paul Kemmeter
Journal:  Surg Endosc       Date:  2019-04-16       Impact factor: 4.584

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.