Literature DB >> 24557753

Applications of different types of gas-permeable contact lenses in keratoconus and their visual results.

Burcu Kazanci1, Dilay Ozek, Alparslan Anayol, Ayşe Balikçi, Dilek Ileri, Pelin Yilmazbaş.   

Abstract

PURPOSE: To show applications of different types of gas-permeable contact lenses in patients with keratoconus and to compare visual acuity (VA) results.
METHODS: A total of 229 eyes of 133 patients who used different types of rigid gas-permeable contact lenses between April 2003 and April 2010 at the Cornea and Contact Lens Unit of Eye Clinic 2 of the Ministry of Health, Ulucanlar Eye Training and Research Hospital, were included. Visual acuity of patients was classified as uncorrected and corrected with eyeglasses and corrected with contact lenses. The patients were compared in terms of VA, daily contact lens wear time, and complications.
RESULTS: A total of 70 out of 133 (52.6%) patients in our study were male, and 63 (47.4%) were female. The mean age was 25.9 ± 7.03 years (12-45). As for the classification of the 229 eyes included in the study, 136 of 229 (59.4%) eyes had moderate keratoconus, 88 (38.4%) had advanced keratoconus, and 5 (2.2%) had severe keratoconus. Following the contact lens application, the VA in all patients increased when compared to uncorrected and corrected with eyeglasses groups and the difference was statistically significant (p<0.005). When a comparison of different types of contact lenses was made, a statistically significant difference was not found (p>0.5) in terms of increase in VA. When patients were evaluated in terms of contact lens wear times, it was observed that Boston Equalens II was preferred by patients wearing lenses 4-8 hours/day. For patients wearing lenses more than 8 hours a day, Rose K lens was used the most. No serious complication was observed in any of the patients that would lead them to stop wearing contact lenses during the follow-up period. There was also no need for keratoplasty in any patient during the follow-up period.
CONCLUSIONS: We detected an increase in VA in patients with rigid contact lenses. In addition, some contact lenses were better tolerated by patients and were used for a longer time during the day.

Entities:  

Mesh:

Year:  2014        PMID: 24557753     DOI: 10.5301/ejo.5000449

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  6 in total

Review 1.  Current perspectives in the management of keratoconus with contact lenses.

Authors:  Li Lim; Elizabeth Wen Ling Lim
Journal:  Eye (Lond)       Date:  2020-07-08       Impact factor: 3.775

2.  Investigation of the efficiency of intrastromal ring segments with cross-linking using different sequence and timing for keratoconus.

Authors:  Xuan-Li Liu; Ping-Hua Li; Pierre Fournie; François Malecaze
Journal:  Int J Ophthalmol       Date:  2015-08-18       Impact factor: 1.779

3.  Contact Lenses for Keratoconus- Current Practice.

Authors:  Marilita M Moschos; Eirini Nitoda; Panagiotis Georgoudis; Miltos Balidis; Eleftherios Karageorgiadis; Nikos Kozeis
Journal:  Open Ophthalmol J       Date:  2017-07-31

4.  Factors Affecting Long-Term Compliance with Rigid Gas-Permeable Contact Lens Wear in Patients with Keratoconus.

Authors:  Yu Xue; Jiaqi Zhou; Zhi Chen; Feng Xue; Li Zeng; Xiaomei Qu; Xingtao Zhou
Journal:  J Clin Med       Date:  2022-02-18       Impact factor: 4.241

5.  Clinical evaluation of flat peripheral curve design with aspherical-curve and multi-curve hard contact lenses for keratoconus.

Authors:  Takashi Kumanomido; Kazutaka Kamiya; Masahide Takahashi; Tatsuhiko Tsujisawa; Hideki Hayakawa; Wakako Ando; Yoshikazu Utsumi; Nobuyuki Shoji
Journal:  PLoS One       Date:  2022-02-08       Impact factor: 3.240

6.  Comparison of Clinical and Topographic Outcomes of Hybrid and Scleral Lenses in Advanced Keratoconus.

Authors:  Betul Ilkay Sezgin Akcay; Alev Kockar; Utku Limon; Esra Kardes; Aslihan Dogan Dursun
Journal:  Beyoglu Eye J       Date:  2021-02-18
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.