Literature DB >> 24556699

Comprehensive evaluations of cone-beam CT dose in image-guided radiation therapy via GPU-based Monte Carlo simulations.

Davide Montanari1, Enrica Scolari, Chiara Silvestri, Yan Jiang Graves, Hao Yan, Laura Cervino, Roger Rice, Steve B Jiang, Xun Jia.   

Abstract

Cone beam CT (CBCT) has been widely used for patient setup in image-guided radiation therapy (IGRT). Radiation dose from CBCT scans has become a clinical concern. The purposes of this study are (1) to commission a graphics processing unit (GPU)-based Monte Carlo (MC) dose calculation package gCTD for Varian On-Board Imaging (OBI) system and test the calculation accuracy, and (2) to quantitatively evaluate CBCT dose from the OBI system in typical IGRT scan protocols. We first conducted dose measurements in a water phantom. X-ray source model parameters used in gCTD are obtained through a commissioning process. gCTD accuracy is demonstrated by comparing calculations with measurements in water and in CTDI phantoms. Twenty-five brain cancer patients are used to study dose in a standard-dose head protocol, and 25 prostate cancer patients are used to study dose in pelvis protocol and pelvis spotlight protocol. Mean dose to each organ is calculated. Mean dose to 2% voxels that have the highest dose is also computed to quantify the maximum dose. It is found that the mean dose value to an organ varies largely among patients. Moreover, dose distribution is highly non-homogeneous inside an organ. The maximum dose is found to be 1-3 times higher than the mean dose depending on the organ, and is up to eight times higher for the entire body due to the very high dose region in bony structures. High computational efficiency has also been observed in our studies, such that MC dose calculation time is less than 5 min for a typical case.

Entities:  

Mesh:

Year:  2014        PMID: 24556699     DOI: 10.1088/0031-9155/59/5/1239

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  13 in total

1.  Use of a laser-guided collimation system to perform direct kilovoltage x-ray spectra measurements on a linear accelerator onboard imager.

Authors:  Zachary Grelewicz; Andrew H Belcher; Rodney D Wiersma
Journal:  Med Phys       Date:  2018-10-09       Impact factor: 4.071

Review 2.  Magnetic resonance image guidance in external beam radiation therapy planning and delivery.

Authors:  Ilamurugu Arivarasan; Chandrasekaran Anuradha; Shanmuga Subramanian; Ayyalusamy Anantharaman; Velayudham Ramasubramanian
Journal:  Jpn J Radiol       Date:  2017-06-13       Impact factor: 2.374

3.  Reconstructing cone-beam CT with spatially varying qualities for adaptive radiotherapy: a proof-of-principle study.

Authors:  Wenting Lu; Hao Yan; Xuejun Gu; Zhen Tian; Ouyang Luo; Liu Yang; Linghong Zhou; Laura Cervino; Jing Wang; Steve Jiang; Xun Jia
Journal:  Phys Med Biol       Date:  2014-09-26       Impact factor: 3.609

4.  Optimization of the geometry and speed of a moving blocker system for cone-beam computed tomography scatter correction.

Authors:  Xi Chen; Luo Ouyang; Hao Yan; Xun Jia; Bin Li; Qingwen Lyu; You Zhang; Jing Wang
Journal:  Med Phys       Date:  2017-09       Impact factor: 4.071

5.  A practical cone-beam CT scatter correction method with optimized Monte Carlo simulations for image-guided radiation therapy.

Authors:  Yuan Xu; Ti Bai; Hao Yan; Luo Ouyang; Arnold Pompos; Jing Wang; Linghong Zhou; Steve B Jiang; Xun Jia
Journal:  Phys Med Biol       Date:  2015-04-10       Impact factor: 3.609

6.  Improving dose calculation accuracy in preclinical radiation experiments using multi-energy element resolved cone-beam CT.

Authors:  Yanqi Huang; Xiaoyu Hu; Yuncheng Zhong; Youfang Lai; Chenyang Shen; Xun Jia
Journal:  Phys Med Biol       Date:  2021-12-06       Impact factor: 3.609

7.  Validation of a deterministic linear Boltzmann transport equation solver for rapid CT dose computation using physical dose measurements in pediatric phantoms.

Authors:  Sara Principi; Yonggang Lu; Yu Liu; Adam Wang; Alex Maslowski; Todd Wareing; John Van Heteren; Taly Gilat Schmidt
Journal:  Med Phys       Date:  2021-10-29       Impact factor: 4.071

8.  Small animal photon counting cone-beam CT on a preclinical radiation research platform to improve radiation dose calculation accuracy.

Authors:  Xiaoyu Hu; Yuncheng Zhong; Youfang Lai; Chenyang Shen; Kai Yang; Xun Jia
Journal:  Phys Med Biol       Date:  2022-09-26       Impact factor: 4.174

9.  Prospective Randomized Trial for Image-Guided Biopsy Using Cone-Beam CT Navigation Compared with Conventional CT.

Authors:  Nadine Abi-Jaoudeh; Teresa Fisher; John Jacobus; Marlene Skopec; Alessandro Radaelli; Imramsjah Martijn Van Der Bom; Robert Wesley; Bradford J Wood
Journal:  J Vasc Interv Radiol       Date:  2016-07-25       Impact factor: 3.464

10.  Deterministic linear Boltzmann transport equation solver for patient-specific CT dose estimation: Comparison against a Monte Carlo benchmark for realistic scanner configurations and patient models.

Authors:  Sara Principi; Adam Wang; Alexander Maslowski; Todd Wareing; Petr Jordan; Taly Gilat Schmidt
Journal:  Med Phys       Date:  2020-10-20       Impact factor: 4.071

View more