Literature DB >> 24556298

Use of Hydrocoil in small aneurysms: procedural safety, treatment efficacy and factors predicting complete occlusion.

Amanda Williams1, John Millar2, Adam Ditchfield2, Sriram Vundavalli3, Simon Barker2.   

Abstract

Coil technology has been directed to reduce recurrence rates and we have seen the introduction of trials comparing the efficacy of surface modified versus bare platinum coils (BPC). This article reports on one treatment strategy in the treatment of small aneurysms by the placement of Hydrocoil across the neck of the aneurysm. Procedural safety, treatment efficacy and factors which predict complete occlusion are evaluated. We retrospectively identified a subgroup of small aneurysms treated over a four-year period. Analysis comparing aneurysms treated with Hydrocoil and BPC versus Hydrocoil alone was undertaken. Eighty-five aneurysms were coiled; 62% with Hydrocoil alone, 38% in combination with BPC. At six-month follow-up, overall 50% were completely occluded, 39.5% had a neck remnant and 10.5% had a residual aneurysm. Complete occlusion was identified in 39% in the Hydrocoil and BPC group compared to 56% in the Hydrocoil alone group. In 56/76 (74%) cases analysed, Hydrocoil loop successfully bridged the neck of the aneurysm in which 38/76 (68%) of these were completely occluded at six-month follow-up. Thirteen procedure-related complications occurred. Aneurysms treated with Hydrocoil alone resulted in fewer recurrences compared with a combination of Hydrocoil and BPC. These data suggest that the technique of positioning Hydrocoil at the neck of the aneurysm increases the probability of complete occlusion and is therefore a strong predictor of aneurysm occlusion. In our experience, this technique did not demonstrate an increased risk of intra-procedural rupture or thrombo-embolic complications compared to conventional embolization with BPC.

Entities:  

Keywords:  embolization; small aneurysms

Mesh:

Year:  2014        PMID: 24556298      PMCID: PMC3971139          DOI: 10.15274/INR-2014-10006

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  13 in total

1.  Hydrogel-coated coils versus bare platinum coils for the endovascular treatment of intracranial aneurysms (HELPS): a randomised controlled trial.

Authors:  Philip M White; Stephanie C Lewis; Anil Gholkar; Robin J Sellar; Hans Nahser; Christophe Cognard; Lynn Forrester; Joanna M Wardlaw
Journal:  Lancet       Date:  2011-05-14       Impact factor: 79.321

2.  HydroCoil for Endovascular Aneurysm Occlusion (HEAL) study: 3-6 month angiographic follow-up results.

Authors:  H J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2007-01       Impact factor: 3.825

3.  Evaluation of the stability of small ruptured aneurysms with a small neck after embolization with Guglielmi detachable coils: correlation between coil packing ratio and coil compaction.

Authors:  Yutaka Kai; Jun-ichiro Hamada; Motohiro Morioka; Shigetoshi Yano; Jun-ichi Kuratsu
Journal:  Neurosurgery       Date:  2005-04       Impact factor: 4.654

4.  Aneurysmal rupture during embolization with Guglielmi detachable coils: causes, management, and outcome.

Authors:  A Doerfler; I Wanke; T Egelhof; U Dietrich; S Asgari; D Stolke; M Forsting
Journal:  AJNR Am J Neuroradiol       Date:  2001 Nov-Dec       Impact factor: 3.825

5.  Endovascular therapy of very small aneurysms of the anterior communicating artery: five-fold increased incidence of rupture.

Authors:  Albert J Schuette; Ferdinand K Hui; Alejandro M Spiotta; Nancy A Obuchowski; Rishi Gupta; Shaye I Moskowitz; Frank C Tong; Jacques E Dion; Charles M Cawley
Journal:  Neurosurgery       Date:  2011-03       Impact factor: 4.654

6.  Thromboembolic Events during Endovascular Coil Embolization of Cerebral Aneurysms.

Authors:  T Ishibashi; Y Murayama; T Saguchi; M Ebara; K Irie; H Takao; T Abe
Journal:  Interv Neuroradiol       Date:  2006-06-15       Impact factor: 1.610

7.  Rupture of intracranial aneurysms during treatment with Guglielmi detachable coils: incidence, outcome, and risk factors.

Authors:  M Sluzewski; J A Bosch; W J van Rooij; P C Nijssen; D Wijnalda
Journal:  J Neurosurg       Date:  2001-02       Impact factor: 5.115

8.  Guglielmi detachable coil embolization of cerebral aneurysms: 11 years' experience.

Authors:  Yuichi Murayama; Yih Lin Nien; Gary Duckwiler; Y Pierre Gobin; Reza Jahan; John Frazee; Neil Martin; Fernando Viñuela
Journal:  J Neurosurg       Date:  2003-05       Impact factor: 5.115

9.  International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion.

Authors:  Andrew J Molyneux; Richard S C Kerr; Ly-Mee Yu; Mike Clarke; Mary Sneade; Julia A Yarnold; Peter Sandercock
Journal:  Lancet       Date:  2005 Sep 3-9       Impact factor: 79.321

10.  Retreatment of ruptured cerebral aneurysms in patients randomized by coiling or clipping in the International Subarachnoid Aneurysm Trial (ISAT).

Authors:  Adriana Campi; Najib Ramzi; Andrew J Molyneux; Paul E Summers; Richard S C Kerr; Mary Sneade; Julia A Yarnold; Joan Rischmiller; James V Byrne
Journal:  Stroke       Date:  2007-03-29       Impact factor: 7.914

View more
  1 in total

Review 1.  Shape Memory Polymer-Based Endovascular Devices: Design Criteria and Future Perspective.

Authors:  Sergio A Pineda-Castillo; Aryn M Stiles; Bradley N Bohnstedt; Hyowon Lee; Yingtao Liu; Chung-Hao Lee
Journal:  Polymers (Basel)       Date:  2022-06-21       Impact factor: 4.967

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.