Literature DB >> 24552299

Four assay designs and on-chip calibration: gadgets for a sepsis protein array.

Patricia Buchegger1, Claudia Preininger.   

Abstract

A protein microarray for the early stage diagnosis of sepsis that allows the simultaneous detection of C-reactive protein (CRP) (2-200 μg/mL), procalcitonin (PCT) (0.2-50 ng/mL), and interleukin 6 (IL-6) (2-2000 pg/mL) has been developed. To enable the parallel detection of the differently abundant analytes, the low binding affinity between CRP and phosphocholine is exploited in a "low-sensitive" sandwich assay for CRP. The calibration is integrated directly on the chip resulting in a "one patient-one array" format, to provide a user-friendly and rapid diagnostic tool. Four different assay designs are introduced: (I) the classical assay that works with biotin-streptavidin chemistry, (II) the rapid assay that is performed in a single detection step, and two ultrasensitive assay designs accomplished either by (III) an enzymatic or (IV) an antibody mediated amplification resulting in high density labeling. The assay designs were evaluated by the repetitive measurement of low, medium, and high concentration levels of commercially available certified control sera. The precision was similar across all assay designs (coefficient of variation (CV), CVintra: 8-14%; CVinter: 18-34%), while the sensitivity (limits of detection (LODs)) increased by 1 order of magnitude for the ultrasensitive assays (III, IV) and the accuracy was analyte dependent but best for the classical (I) and the antibody amplified (IV) assays.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24552299     DOI: 10.1021/ac5000784

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  A dual signal-amplified electrochemiluminescence immunosensor based on core-shell CeO2-Au@Pt nanosphere for procalcitonin detection.

Authors:  Xinrong Shao; Xianzhen Song; Xin Liu; Liangguo Yan; Lei Liu; Dawei Fan; Qin Wei; Huangxian Ju
Journal:  Mikrochim Acta       Date:  2021-09-16       Impact factor: 5.833

2.  Magnetic Bead-Based Electrochemical Immunoassays On-Drop and On-Chip for Procalcitonin Determination: Disposable Tools for Clinical Sepsis Diagnosis.

Authors:  Águeda Molinero-Fernández; María Moreno-Guzmán; Miguel Ángel López; Alberto Escarpa
Journal:  Biosensors (Basel)       Date:  2020-06-17

3.  Hydrogel based protein biochip for parallel detection of biomarkers for diagnosis of a Systemic Inflammatory Response Syndrome (SIRS) in human serum.

Authors:  Anne Stumpf; Thomas Brandstetter; Johannes Hübner; Jürgen Rühe
Journal:  PLoS One       Date:  2019-12-02       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.