Literature DB >> 24550090

Extended follow-up following "full-metal jacket" percutaneous coronary interventions with drug-eluting stents.

Sandeep Basavarajaiah1, Toru Naganuma, Azeem Latib, Tasuku Hasegawa, Andrew Sharp, Ahmed Rezq, Alessandro Sticchi, Filipo Figini, Antonio Amato, Antonio Colombo.   

Abstract

OBJECTIVES: To report very long-term follow-up of "Full-Metal Jacket" (FMJ) percutaneous coronary interventions (PCI) in long-diffuse coronary lesions with drug-eluting stents (DES).
BACKGROUND: PCI for long-diffuse lesions may result in FMJ, which is not preferred by some operators due to long-term risk of restenosis and stent thrombosis. The data on long-term follow-up of patients with FMJ are limited and would be useful in understanding the safety and feasibility of such a strategy.
METHODS: Between April 2002 and March 2007, 274 patients (297 lesions in native coronary arteries) underwent PCI utilizing DES. FMJ was described as lesions requiring ≥ 60 mm of continuous stent. The measured endpoints were cardiac death, target-vessel myocardial infarction (MI), target lesion revascularization (TLR), target-vessel revascularization (TVR), and major adverse cardiac events (MACE) defined as composite of cardiac death, target-vessel MI, and TVR.
RESULTS: The mean age of patients was 62.1 ± 11 years. The mean length of total stents used was 75.1 ± 16.4 mm (60-150). During the median follow-up of 74.7 months (interquartile range: 58-96), the rates of cardiac death, MI, TLR, and TVR were: 5.8% (n = 16), 6.2% (n = 17), 27.3% (n = 81), and 30% (n = 89), respectively. The MACE rate was 34%. Definite and probable stent thrombosis occurred in 10 patients (3.6%).
CONCLUSION: The long-term follow-up of patients with FMJ is acceptable especially in regards to hard endpoints (death and MI) given the complexity of lesions treated. The high MACE rate was driven mainly by TVR. The availability of newer-generation DES and bioabsorbable scaffolds may improve these results.
© 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  drug-eluting stents; full-metal jacket; long-diffuse lesions

Mesh:

Year:  2014        PMID: 24550090     DOI: 10.1002/ccd.25455

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  2 in total

1.  Comparison of mid-term clinical outcomes between on-label and off-label use of rotational atherectomy.

Authors:  Takayuki Mori; Kenichi Sakakura; Hiroshi Wada; Yousuke Taniguchi; Kei Yamamoto; Yusuke Adachi; Hiroshi Funayama; Shin-Ichi Momomura; Hideo Fujita
Journal:  Heart Vessels       Date:  2016-10-05       Impact factor: 2.037

Review 2.  Ivabradine in Patients with Stable Coronary Artery Disease: A Rationale for Use in Addition to and Beyond Percutaneous Coronary Intervention.

Authors:  Cosmo Godino; Antonio Colombo; Alberto Margonato
Journal:  Clin Drug Investig       Date:  2017-02       Impact factor: 2.859

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.