| Literature DB >> 24549046 |
Angelika Kunze1, Camilla Hesse2, Sofia Svedhem3.
Abstract
For the development of advanced hemocompatible biomaterial functions, there is an unmet demand for in vitro evaluation techniques addressing platelet-surface interactions. We show that the quartz crystal microbalance with dissipation (QCM-D) monitoring technique, here combined with light microscopy, provides a surface sensitive technique that allows for real-time monitoring of the activation and aggregation of the surface-confined platelets on TiO2. The QCM-D signal monitored during adhesion and activation of platelets on TiO2 coated surfaces was found to be different in platelet-poor and platelet-rich environment although light microscopy images taken for each of the two cases looked essentially the same. Interestingly, aggregation of activated platelets was only observed in a protein-rich environment. Our results show that a layer of plasma proteins between the TiO2 surface and the platelets strongly influences the coupling between the platelets and the underlying substrate, explaining both the observed QCM-D signals and the ability of the platelets to aggregate.Entities:
Keywords: Aggregation; Platelet activation; QCM-D; TiO(2)
Mesh:
Substances:
Year: 2014 PMID: 24549046 DOI: 10.1016/j.colsurfb.2014.01.025
Source DB: PubMed Journal: Colloids Surf B Biointerfaces ISSN: 0927-7765 Impact factor: 5.268