Literature DB >> 24534552

Disposable amperometric biosensor based on lactate oxidase immobilised on platinum nanoparticle-decorated carbon nanofiber and poly(diallyldimethylammonium chloride) films.

Pedro J Lamas-Ardisana1, Oscar A Loaiza2, Larraitz Añorga2, Elena Jubete2, Maryam Borghei3, Virginia Ruiz2, Estibalitz Ochoteco2, Germán Cabañero2, Hans J Grande2.   

Abstract

A novel biosensor for lactate has been developed, using screen-printed carbon electrodes (SPCE) and lactate oxidase (LOx). The active surface of the electrodes was modified using a dispersion of platinum nanoparticle decorated carbon nanofibers (PtNp-CNF) in poly(diallyldimethylammonium) chloride (PDDA) solution. In this way, sensitive, disposable, low cost and reliable hydrogen peroxide sensors were obtained. The immobilisation of LOx on top of these PtNp-CNF-PDDA/SPCEs resulted in amperometric biosensors with high operational stability. The sensitivity of the optimised lactate biosensor was 36.8 (mA/Mcm(2)) with a linear range of 25-1500 µM. The limit of detection was 11 µM (S/N=3). Reproducibility, selectivity and storage stability were also evaluated. Additionally, the stability of the biosensor was also predicted by a model based on thermal degradation. Finally, lactate in sweat and blood samples was determined in a sport test using LOx/PtNp-CNF-PDDA/SPCEs and commercial biosensors respectively. Based on these data, the validity of the sweat lactate for the determination of the lactate threshold is discussed.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Carbon nanofiber; Lactate; Lactate oxidase; Platinum nanoparticle; Screen-printed electrode; Sweat

Mesh:

Substances:

Year:  2014        PMID: 24534552     DOI: 10.1016/j.bios.2014.01.047

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  16 in total

1.  A nanocomposite prepared from platinum particles, polyaniline and a Ti3C2 MXene for amperometric sensing of hydrogen peroxide and lactate.

Authors:  Supawat Neampet; Nipapan Ruecha; Jiaqian Qin; Wanida Wonsawat; Orawon Chailapakul; Nadnudda Rodthongkum
Journal:  Mikrochim Acta       Date:  2019-11-07       Impact factor: 5.833

Review 2.  Advances in the design of nanomaterial-based electrochemical affinity and enzymatic biosensors for metabolic biomarkers: A review.

Authors:  Leila Farzin; Mojtaba Shamsipur; Leila Samandari; Shahab Sheibani
Journal:  Mikrochim Acta       Date:  2018-05-02       Impact factor: 5.833

Review 3.  Microfluidic wearable electrochemical sweat sensors for health monitoring.

Authors:  Balaji Ramachandran; Ying-Chih Liao
Journal:  Biomicrofluidics       Date:  2022-09-26       Impact factor: 3.258

4.  Reagent-Less and Robust Biosensor for Direct Determination of Lactate in Food Samples.

Authors:  Iria Bravo; Mónica Revenga-Parra; Félix Pariente; Encarnación Lorenzo
Journal:  Sensors (Basel)       Date:  2017-01-13       Impact factor: 3.576

Review 5.  Wearable Chemosensors: A Review of Recent Progress.

Authors:  Ruo-Can Qian; Yi-Tao Long
Journal:  ChemistryOpen       Date:  2017-12-07       Impact factor: 2.911

6.  A quasi-reagentless point-of-care test for nitrite and unaffected by oxygen and cyanide.

Authors:  Tiago Monteiro; Sara Gomes; Elena Jubete; Larraitz Añorga; Célia M Silveira; Maria Gabriela Almeida
Journal:  Sci Rep       Date:  2019-02-22       Impact factor: 4.379

7.  Bendable Electro-chemical Lactate Sensor Printed with Silver Nano-particles.

Authors:  Md Abu Abrar; Yue Dong; Paul Kyuheon Lee; Woo Soo Kim
Journal:  Sci Rep       Date:  2016-07-28       Impact factor: 4.379

8.  A Self-Powered Biosensor for Monitoring Maximal Lactate Steady State in Sport Training.

Authors:  Yupeng Mao; Wen Yue; Tianming Zhao; MaiLun Shen; Bing Liu; Song Chen
Journal:  Biosensors (Basel)       Date:  2020-07-08

Review 9.  Sensors for Fetal Hypoxia and Metabolic Acidosis: A Review.

Authors:  Gerard Cummins; Jessica Kremer; Anne Bernassau; Andrew Brown; Helen L Bridle; Holger Schulze; Till T Bachmann; Michael Crichton; Fiona C Denison; Marc P Y Desmulliez
Journal:  Sensors (Basel)       Date:  2018-08-13       Impact factor: 3.576

10.  Enhanced Performance of Reagent-Less Carbon Nanodots Based Enzyme Electrochemical Biosensors.

Authors:  Iria Bravo; Cristina Gutiérrez-Sánchez; Tania García-Mendiola; Mónica Revenga-Parra; Félix Pariente; Encarnación Lorenzo
Journal:  Sensors (Basel)       Date:  2019-12-17       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.