Literature DB >> 24533582

Early Loading of Fluoridated Implants Placed in Fresh Extraction Sockets and Healed Bone: A 3- to 5-Year Clinical and Radiographic Follow-Up Study of 39 Consecutive Patients.

Gert Oxby1, Fredrik Oxby1, Johan Oxby1, Tomas Saltvik1, Peter Nilsson2,3.   

Abstract

BACKGROUND: Immediate placement of implants in extraction sockets for early loading is an attractive treatment modality due to reduced treatment time. However, the outcome of fluoridated implants in this situation with regard to bone levels and health of soft tissues is not well documented.
PURPOSE: To evaluate the outcome of early loading of OsseoSpeed(™) dental implants placed into fresh extraction sockets and healed bone in consecutive patients treated in a private clinic.
MATERIALS AND METHODS: A total of 182 OsseoSpeed(™) implants (Astra Tech Implant System, DENTSPLY Implants, Mölndal, Sweden), 72 in immediate extraction sockets and 110 in healed sites, were placed in 39 consecutive patients. The implants were loaded with permanent restorations within 60 days (average 31 days). Clinical and radiographic follow-up examinations were performed annually for at least 3 years (mean 55 months). An aesthetic index was used to evaluate the soft tissues adjacent to the prosthetic restorations.
RESULTS: No implant was lost during the observation period, giving a survival rate of 100%. Bone level changes during the observation period were minimal, with a mean marginal bone loss of 0.3 ± 0.9 mm around the delayed implants and a mean marginal bone gain of 0.3 ± 1.4 mm around the immediate implants (p = .0036). The frequency distribution of bone level revealed that 85% of implants placed in fresh extraction sockets and 84% of implants in healed bone did not show any loss of bone level during follow-up (p = NS). Soft tissue complications were observed at two immediate implant sites in one patient. The remaining 180 implants received the highest aesthetic score. Moreover, no signs of peri-implant purulent infection or aggressive bone loss were found during the follow-up period.
CONCLUSION: Early loading of fluoridated implants with permanent constructions appears to be a viable therapy for implants placed immediately in extraction sites and in healed bone.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  aesthetics; dental implants; early loading; extraction sockets; radiography

Mesh:

Substances:

Year:  2014        PMID: 24533582     DOI: 10.1111/cid.12210

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  5 in total

1.  Comparative evaluation of the stability of two different dental implant designs and surgical protocols-a pilot study.

Authors:  David E Simmons; Pooja Maney; Austin G Teitelbaum; Susan Billiot; Lomesh J Popat; A Archontia Palaiologou
Journal:  Int J Implant Dent       Date:  2017-05-02

Review 2.  Modifications of Dental Implant Surfaces at the Micro- and Nano-Level for Enhanced Osseointegration.

Authors:  In-Sung Luke Yeo
Journal:  Materials (Basel)       Date:  2019-12-23       Impact factor: 3.623

Review 3.  Does the timing of implant placement and loading influence biological outcomes of implant-supported multiple-unit fixed dental prosthesis-A systematic review with meta-analyses.

Authors:  Louise Leite Aiquel; João Pitta; Georgios N Antonoglou; Irene Mischak; Irena Sailer; Michael Payer
Journal:  Clin Oral Implants Res       Date:  2021-10       Impact factor: 5.021

4.  Effect of platform switching on crestal bone levels around implants in the posterior mandible: 3 years results from a multicentre randomized clinical trial.

Authors:  Salomão Rocha; Wilfried Wagner; Jörg Wiltfang; Pedro Nicolau; Maximilian Moergel; Ana Messias; Eleonore Behrens; Fernando Guerra
Journal:  J Clin Periodontol       Date:  2016-03-30       Impact factor: 8.728

Review 5.  Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis.

Authors:  Adam Ibrahim; Bruno Ramos Chrcanovic
Journal:  Materials (Basel)       Date:  2021-12-20       Impact factor: 3.623

  5 in total