Literature DB >> 24532434

Safe zone for superolateral entry pin into the distal humerus in children: an MRI analysis.

Tamir Bloom1, Caixia Zhao, Alpesh Mehta, Uma Thakur, John Koerner, Sanjeev Sabharwal.   

Abstract

BACKGROUND: The radial nerve is at risk for iatrogenic injury during placement of pins, screws, or wires around the distal humerus. Unlike adults, detailed anatomic information about the relationship of the nerve to the distal humerus is lacking in children. QUESTION/PURPOSES: This study evaluates the relationship of the radial nerve to the distal humerus in a pediatric population on conventional MRI and proposes an anatomic safe zone using easily identifiable bony landmarks on an AP elbow radiograph.
METHODS: To determine the course of the radial nerve at the lateral distal humerus, we reviewed 23 elbow radiographs and MRIs of 22 children (mean age, 9 ± 4 years; range, 3-12 years) obtained as part of their workup for various elbow conditions. We described a technique using distance ratios calculated as a percentage of the patient's own transepicondylar distance, defined as the distance measured between the apices of the medial and lateral epicondyles, on the AP elbow radiograph and the midcoronal MR image. The cross-reference tool on a Picture Archiving and Communication System was then used to identify axial MR image at the level where the transepicondylar distance was measured. On this axial image, a line was drawn connecting the medial and lateral epicondyles (the transepicondylar axis) and its midpoint was determined. The radial nerve angle was measured by a line from the radial nerve to the midpoint of the transepicondylar axis and a line along the lateral half of the transepicondylar axis. On this axial slice, the closest distance from the nerve to the underlying cortex of the distal humerus was measured. To further localize the nerve along the distal humerus, predetermined percentages of the transepicondylar distance were projected proximally from the level of the transepicondylar axis along the longitudinal axis of the humerus on the midcoronal MR image. At these designated heights, the corresponding axial MR image was identified using the cross-reference tool and the nerve was mapped in a similar fashion. We then proposed a simpler method using a best-fit line drawn along the lateral supracondylar ridge on the AP radiograph to define the safe zone for lateral pin entry.
RESULTS: On axial MR images, the radial nerve was located in the anterolateral quadrant with a mean radial nerve angle of 54° (range, 35°-87) at 0% transepicondylar distance (23 MRIs), 41° (range, 24°-63°) at 50% transepicondylar distance (23 MRIs), and ≥ 10° at 75% transepicondylar distance (on the 13 MRIs that extended this far cephalad). The mean closest distance between the radial nerve and the underlying humeral cortex was 10 mm (range, 3-26 mm) at 0% transepicondylar distance and 7 mm (3-16 mm) at 50% transepicondylar distance. On the AP elbow radiograph, the height of the lateral supracondylar ridge, determined by a best-fit line drawn along the lateral cortex of the ridge, diverged from the most proximal extent of the ridge at a point located at 60% transepicondylar distance (range, 51%-76%). At the corresponding location on the axial MR image, the nerve was located anterolaterally with a mean radial nerve angle of 39° (range, 15°-61°) and a mean distance of 6 mm (range, 2-10 mm) from the underlying humerus.
CONCLUSIONS: Our data suggest that percutaneous direct lateral entry Kirschner wires and half-pins can be safely inserted in the distal humerus in children along the transepicondylar axis, either at or slightly posterior to the lateral supracondylar ridge, when placed caudal to the point located where the lateral supracondylar ridge line diverges from the proximal extent of the supracondylar ridge on AP elbow radiograph.

Entities:  

Mesh:

Year:  2014        PMID: 24532434      PMCID: PMC4397742          DOI: 10.1007/s11999-014-3509-x

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  32 in total

Review 1.  Upper extremity peripheral nerve anatomy: current concepts and applications.

Authors:  M T Mazurek; A Y Shin
Journal:  Clin Orthop Relat Res       Date:  2001-02       Impact factor: 4.176

2.  Extensile approach to the anterolateral surface of the humerus and the radial nerve.

Authors:  A O Mekhail; A J Checroun; N A Ebraheim; W T Jackson; R A Yeasting
Journal:  J Shoulder Elbow Surg       Date:  1999 Mar-Apr       Impact factor: 3.019

3.  Humeral lengthening and deformity correction with the multiaxial correction system.

Authors:  Alexander S McLawhorn; Seth L Sherman; Arkady Blyakher; Roger F Widmann
Journal:  J Pediatr Orthop B       Date:  2011-03       Impact factor: 1.041

4.  Lengthening and deformity correction of the upper extremity by the Ilizarov technique.

Authors:  K Tetsworth; J Krome; D Paley
Journal:  Orthop Clin North Am       Date:  1991-10       Impact factor: 2.472

5.  Anatomical basis of the risk of radial nerve injury related to the technique of external fixation applied to the distal humerus.

Authors:  Hans Clement; Wolfgang Pichler; Norbert Peter Tesch; Nima Heidari; Wolfgang Grechenig
Journal:  Surg Radiol Anat       Date:  2009-10-06       Impact factor: 1.246

6.  Unilateral external fixator in the treatment of lower third humeral shaft fractures.

Authors:  Zhen-zhou Li; Shu-xun Hou; Ke-jian Wu; Wei-jia Zhang; Wen-feng Li; Wei-lin Shang; Wen-wen Wu
Journal:  Chin J Traumatol       Date:  2005-08

7.  Iatrogenic radial nerve injury with cannulated fixation of medial epicondyle fractures in the pediatric humerus: a report of 2 cases.

Authors:  David M Marcu; Joshua Balts; James J McCarthy; Scott H Kozin; Kenneth J Noonan
Journal:  J Pediatr Orthop       Date:  2011-03       Impact factor: 2.324

8.  "Dorgan's" percutaneous lateral cross-wiring of supracondylar fractures of the humerus in children.

Authors:  Fintan J Shannon; Prashant Mohan; Jacob Chacko; Lester G D'Souza
Journal:  J Pediatr Orthop       Date:  2004 Jul-Aug       Impact factor: 2.324

9.  Management of recurrent, complex instability of the elbow with a hinged external fixator.

Authors:  M D McKee; S H Bowden; G J King; S D Patterson; J B Jupiter; H B Bamberger; N Paksima
Journal:  J Bone Joint Surg Br       Date:  1998-11

10.  Complications of hinged external fixators of the elbow.

Authors:  Emilie V Cheung; Shawn W O'Driscoll; Bernard F Morrey
Journal:  J Shoulder Elbow Surg       Date:  2008-03-04       Impact factor: 3.019

View more
  1 in total

Review 1.  The Pulseless Supracondylar Elbow Fracture: A Rational Approach.

Authors:  Samir Sabharwal; Adam Margalit; Ishaan Swarup; Sanjeev Sabharwal
Journal:  Indian J Orthop       Date:  2020-10-13       Impact factor: 1.251

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.