Literature DB >> 24530180

Reinforced aneurysmorrhaphy for true aneurysmal haemodialysis vascular access.

S Rokošný1, P Baláž2, P Wohlfahrt3, D Palouš4, L Janoušek5.   

Abstract

OBJECTIVE: In 2008, a new technique of reinforced aneurysmorrhaphy with a polyester mesh tube for salvaging true aneurysmal arteriovenous (AV) haemodialysis access was described by us. In this study, the long-term patency and complication rates associated with this procedure were analysed, and the effect of reinforced aneurysmorrhaphy on high-flow vascular access was assessed.
METHODS: This was a retrospective non-randomised study with prospectively collected data performed at a single centre. Patients with true aneurysmal haemodialysis AV access who underwent aneurysmorrhaphy with external mesh prosthesis between March 2007 and October 2012 were included. Clinical assessment and duplex ultrasound were performed preoperatively, 1, 3, and 12 months postoperatively, and annually thereafter.
RESULTS: Data from 62 patients (median age 60 years, range 28-81 years; 63% men) were analysed. The commonest indication was high-flow vascular access associated with the risk of high output cardiac failure (24 patients, 39%). The mean follow-up time was 14.66 ± 12.80 months. Primary patency rates at 6 and 12 months were 86% and 79% respectively. Assisted primary patency rates at 6 and 12 months were 89% and 80% respectively. In 23 patients (96%) operated on for high-flow vascular access, decreased vascular access flow was observed after the procedure. The average flow reduction after aneurysmorrhaphy was 2,197 mL/minute. Postoperative bleeding and infection necessitating surgical revision occurred in three (4.8%) and three (4.8%) patients respectively.
CONCLUSIONS: Reinforced aneurysmorrhaphy with an external mesh prosthesis is an effective method for treating true aneurysmal haemodialysis AV access, with excellent long-term patency and minimal complications due to infection.
Copyright © 2014 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Aneurysm; Aneurysmorrhaphy; Arteriovenous access; External mesh prosthesis; High-flow access

Mesh:

Year:  2014        PMID: 24530180     DOI: 10.1016/j.ejvs.2014.01.010

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  4 in total

1.  Stent graft deployment in haemodialysis fistula: patency rates in partially thrombosed aneurysm and residual thrombi.

Authors:  José García-Medina; Ana B Maldonado-Cárceles; Juan J García-Alfonso; Julián J Árense-Gonzalo; Alberto M Torres-Cantero
Journal:  Clin Kidney J       Date:  2020-02-10

2.  Cardiac remodeling after reduction of high-flow arteriovenous fistulas in end-stage renal disease.

Authors:  Peter Wohlfahrt; Slavomir Rokosny; Vojtech Melenovsky; Barry A Borlaug; Vera Pecenkova; Peter Balaz
Journal:  Hypertens Res       Date:  2016-05-26       Impact factor: 3.872

3.  Graft Inclusion Technique: A New Flow Reduction Procedure for High Flow Arteriovenous Fistulae.

Authors:  Takehisa Nojima; Yasuki Motomiya
Journal:  Ann Vasc Dis       Date:  2018-06-25

4.  Upper extremity reconstruction following open surgical repair of giant arteriovenous fistula aneurysm: clinical case and systematic review of the literature.

Authors:  Tariq A Almerey; Jeremie D Oliver; Matthew S Jorgensen; Brian D Rinker; Houssam A Farres; Albert G Hakaim; Antonio Jorge Forte
Journal:  Acta Biomed       Date:  2020-11-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.