Beyond auscultation: acoustic cardiography in clinical practice.

Yong-Na Wen1, Alex Pui-Wai Lee1, Fang Fang1, Chun-Na Jin1, Cheuk-Man Yu2.   

Abstract

Cardiac auscultation by stethoscope is widely used but limited by low sensitivity and accuracy. Phonocardiogram was developed in an attempt to provide quantitative and qualitative information of heart sounds and murmurs by transforming acoustic signal into visual wavelet. Although phonocardiogram provides objective heart sound information and holds diagnostic potentials of different heart problems, its examination procedure is time-consuming and it requires specially trained technicians to operate the device. Acoustic cardiography (AUDICOR, Inovise Medical, Inc., Portland, OR, USA) is a major recent advance in the evolution of cardiac auscultation technology. The technique is more efficient and less operator-dependent. It synchronizes cardiac auscultation with ECG recording and provides a comprehensive assessment of both mechanical and electronic function of the heart. The application of acoustic cardiography is far beyond auscultation only. It generates various parameters which have been proven to correlate with gold standards in heart failure diagnosis and ischemic heart disease detection. Its application can be extended to other diseases, including LV hypertrophy, constrictive pericarditis, sleep apnea and ventricular fibrillation. The newly developed ambulatory acoustic cardiography is potentially used in heart failure follow-up in both home and hospital setting. This review comprehensively summarizes acoustic cardiographic research, including the most recent development.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  AUDICOR; Acoustic cardiography; Phonocardiography

Mesh:

Year:  2014        PMID: 24529949     DOI: 10.1016/j.ijcard.2013.12.298

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  9 in total

1.  How to Improve Time to Diagnosis in Acute Heart Failure - Clinical Signs and Chest X-ray.

Authors:  Christopher J Allen; Kaushik Guha; Rakesh Sharma
Journal:  Card Fail Rev       Date:  2015-10

2.  Use of acoustic cardiography immediately following electrical cardioversion to predict relapse of atrial fibrillation.

Authors:  Paul Erne; Therese J Resink; Andrea Mueller; Michael Coslovsky; Richard Kobza; David Conen; Peter Bauer; Patricia Arand
Journal:  J Atr Fibrillation       Date:  2017-06-30

3.  Characterization of cardiac acoustic biomarkers in patients with heart failure.

Authors:  Daniel Burkhoff; Grant Bailey; J Rod Gimbel
Journal:  Ann Noninvasive Electrocardiol       Date:  2019-10-16       Impact factor: 1.468

4.  Night-time electromechanical activation time, pulsatile hemodynamics, and discharge outcomes in patients with acute heart failure.

Authors:  Chun-Chin Chang; Shih-Hsien Sung; Wen-Chung Yu; Hao-Min Cheng; Chen-Huan Chen
Journal:  ESC Heart Fail       Date:  2015-07-14

5.  New non-invasive approach to detect cardiac contractility using the first sound of phonocardiogram.

Authors:  Koichi Yamashita
Journal:  Acute Med Surg       Date:  2020-01-22

6.  Changes in acoustic cardiographic parameters before and after hemodialysis are associated with overall and cardiovascular mortality in hemodialysis patients.

Authors:  Tung-Ling Chung; Yi-Hsueh Liu; Jiun-Chi Huang; Pei-Yu Wu; Szu-Chia Chen; Jer-Ming Chang
Journal:  Sci Rep       Date:  2021-01-15       Impact factor: 4.379

7.  Use of proposed systolic and myocardial performance indices derived from simultaneous ECG and PCG recordings to assess cardiac function in healthy Beagles.

Authors:  Karlo Romano B Gicana; Chirutchaya Pinidmontree; Kitchanan Kosalathip; Siraphop Sirirut; Siripen Komolvanich; Sariya Asawakarn; Walasinee Sakcamduang; Phornphop Naiyanetr; Kittipong Tachampa
Journal:  Vet World       Date:  2022-07-25

8.  Beat-to-Beat Tracking of Pulse Pressure and Its Respiratory Variation Using Heart Sound Signal in Patients Undergoing Liver Transplantation.

Authors:  Yong-Seok Park; Young-Jin Moon; Sung-Hoon Kim; Jae-Man Kim; Jun-Gol Song; Gyu-Sam Hwang
Journal:  J Clin Med       Date:  2019-04-30       Impact factor: 4.241

9.  Investigation of Acoustic Cardiographic Parameters before and after Hemodialysis.

Authors:  Hui-Ju Tsai; Yi-Chun Tsai; Jiun-Chi Huang; Pei-Yu Wu; Szu-Chia Chen; Yi-Wen Chiu; Jer-Ming Chang; Hung-Chun Chen
Journal:  Dis Markers       Date:  2019-11-05       Impact factor: 3.434

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.