Literature DB >> 24529003

Thoracic bioelectrical impedance assessment of the hemodynamic reactions to recorded road-traffic noise in young adults.

Katarina Paunović1, Vesna Stojanov2, Branko Jakovljević3, Goran Belojević3.   

Abstract

Noise exposure increases blood pressure in both experimental and field studies. The underlying mechanisms may be evaluated by thoracic bioelectrical impedance. The aim of this experimental study was to assess changes in blood pressure, cardiac and hemodynamic parameters provoked by recorded traffic noise in young adults. The study included 130 participants (42 men and 88 women), aged 24.88±2.67 years. Thoracic electrical bioimpedance device was applied to monitor cardiac parameters, hemodynamic parameters, heart rate variability, blood pressure and heart rate. The testing procedure consisted of three phases. Participants were exposed to recorded road-traffic noise (Leq=89dBA) for 10min and relaxed in quiet conditions (Leq=40dBA) before and after noise exposure. Listening to recorded noise resulted in significant decrease of stroke volume and cardiac output, and an increase of vascular resistance. Heart rate variability and the overall sympathovagal balance remained similar through all experimental conditions. During noise exposure, systolic pressure increased by 2mmHg among women (95% confidence interval=0.97-2.73mmHg), and by 4mmHg among men (95% confidence interval=2.16-5.00mmHg). Similarly, diastolic pressure increased by 2mmHg among women (95% confidence interval=0.95-2.47mmHg), and by 4mmHg among men (95% confidence interval=2.46-5.28mmHg). Once noise ceased, both pressures returned to pre-exposure levels. Experimental exposure to recorded road-traffic noise of 89dBA for 10min provoked significant hemodynamic changes in young adults, including vasoconstriction (increase of vascular resistance), and hypodynamics (decrease of global heart flow). The interaction of these effects resulted in the elevation of blood pressure during noise exposure.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Blood pressure; Hemodynamics; Impedance cardiography; Noise

Mesh:

Year:  2014        PMID: 24529003     DOI: 10.1016/j.envres.2014.01.001

Source DB:  PubMed          Journal:  Environ Res        ISSN: 0013-9351            Impact factor:   6.498


  2 in total

Review 1.  ICBEN review of research on the biological effects of noise 2011-2014.

Authors:  Mathias Basner; Mark Brink; Abigail Bristow; Yvonne de Kluizenaar; Lawrence Finegold; Jiyoung Hong; Sabine A Janssen; Ronny Klaeboe; Tony Leroux; Andreas Liebl; Toshihito Matsui; Dieter Schwela; Mariola Sliwinska-Kowalska; Patrik Sörqvist
Journal:  Noise Health       Date:  2015 Mar-Apr       Impact factor: 0.867

2.  A Wrapper Feature Selection Algorithm: An Emotional Assessment Using Physiological Recordings from Wearable Sensors.

Authors:  Inma Mohino-Herranz; Roberto Gil-Pita; Joaquín García-Gómez; Manuel Rosa-Zurera; Fernando Seoane
Journal:  Sensors (Basel)       Date:  2020-01-06       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.