Literature DB >> 2452561

Balloon pulmonary valvuloplasty for congenital cyanotic heart defects.

P S Rao1, M Brais.   

Abstract

Eight infants with congenital cyanotic heart defects, aged 7 days to 10 months, weighing 2.9 to 10.0 kg, underwent percutaneous balloon pulmonary valvuloplasty as a palliative procedure to improve pulmonary oligemia. The indication for valvuloplasty was cyanotic heart defect not amenable to total surgical correction at the age and size at presentation but at the same time requiring palliation of pulmonary oligemia. After balloon valvuloplasty, there was an increase in the pulmonary blood flow index (1.83 +/- 0.55 to 3.14 +/- 1.38 L/min/m2; p less than 0.05), pulmonary-to-systemic flow ratio (0.55 +/- 0.35 to 1.19 +/- 0.63; p less than 0.05), and pulmonary artery pressure (15.5 +/- 6.6 to 29.1 +/- 12.1 mm Hg; p less than 0.02). Arterial oxygen saturation, although increased from 69.6 +/- 11.5% to 81.4 +/- 12.3%, did not attain statistical significance (p greater than 0.05). Immediate surgical intervention was avoided in all eight patients. At follow-up, 4 to 12 months after balloon valvuloplasty, all infants were thriving with decreased hypoxemia and polycythemia. Follow-up catheterization data were available from six patients, 3 to 10 months after valvuloplasty, and in all of them the immediate postballoon valvuloplasty improvement persisted or further improvement noted. These data suggest that pulmonary valvuloplasty offers excellent palliation of pulmonary oligemia in cyanotic heart defects, thus avoiding the risks of immediate surgical palliation and paving the way for a better result of eventual total surgical correction.

Entities:  

Mesh:

Year:  1988        PMID: 2452561     DOI: 10.1016/0002-8703(88)90083-x

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  11 in total

Review 1.  Surgical management of congenital heart defects: current trends.

Authors:  P S Chopra; P S Rao
Journal:  Indian J Pediatr       Date:  1991 Sep-Oct       Impact factor: 1.967

Review 2.  The neonate with congenital heart disease: diagnosis and management.

Authors:  B Chandramouli
Journal:  Indian J Pediatr       Date:  1991 Jul-Aug       Impact factor: 1.967

Review 3.  Fontan Operation: Indications, Short and Long Term Outcomes.

Authors:  P Syamasundar Rao
Journal:  Indian J Pediatr       Date:  2015-06-20       Impact factor: 1.967

4.  The Journey of an Indian Pediatric Cardiologist : Dr. K. C. Chaudhuri Lifetime Achievement Award/Oration at AIIMS, New Delhi, September 2017.

Authors:  P Syamasundar Rao
Journal:  Indian J Pediatr       Date:  2017-09-27       Impact factor: 1.967

5.  Results of three to 10 year follow up of balloon dilatation of the pulmonary valve.

Authors:  P S Rao; O Galal; M Patnana; S H Buck; A D Wilson
Journal:  Heart       Date:  1998-12       Impact factor: 5.994

6.  Balloon dilation of the pulmonary valve in premature infants with tetralogy of Fallot.

Authors:  Vikas Kohli; Sushil Azad; Manvinder Singh Sachdev; Reena Joshi; Raja Joshi; Makram R Ebeid; Ebeid R Makram
Journal:  Pediatr Cardiol       Date:  2008-07-29       Impact factor: 1.655

Review 7.  Diagnosis and management of cyanotic congenital heart disease: part I.

Authors:  P Syamasundar Rao
Journal:  Indian J Pediatr       Date:  2009-04-18       Impact factor: 1.967

Review 8.  Consensus on timing of intervention for common congenital heart diseases: part II - cyanotic heart defects.

Authors:  P Syamasundar Rao
Journal:  Indian J Pediatr       Date:  2013-05-03       Impact factor: 1.967

9.  Management of Congenital Heart Disease: State of the Art-Part II-Cyanotic Heart Defects.

Authors:  P Syamasundar Rao
Journal:  Children (Basel)       Date:  2019-04-04

Review 10.  Single Ventricle-A Comprehensive Review.

Authors:  P Syamasundar Rao
Journal:  Children (Basel)       Date:  2021-05-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.