| Literature DB >> 24520439 |
Nahid Nasiri1, Ahmad Vosoughtaqi Dizaj2, Poopak Eftekhari-Yazdi1, Mohammad Reza Akhond3.
Abstract
BACKGROUND: There is a lack of studies regarding the effects of ultrasound (US) and replication of its exposure on pre-implantation events in mammals. Thus, this study assesses the reproductive performance of mouse oocytes that have been obtained from ovaries irradiated with US waves versus non-irradiated ovaries. Also comparision of their parthenogenesis, ovulation, fertilization, and pre-implantation development rates.Entities:
Keywords: Blastocyst; Fertilization Rate; Mouse Oocyte; Parthenogenesis; Ultrasound
Year: 2012 PMID: 24520439 PMCID: PMC3850303
Source DB: PubMed Journal: Int J Fertil Steril ISSN: 2008-0778
Fig 1The exposure system and mouse fulcrum. The chamber of system was filled with degassed water. The cyclic section from the center of the left lid was removed, and the US probe was positioned centrally and perpendicular to the chamber. The anesthetized mouse was placed on the cubic piece of yonolit at the opposite end of the chamber. The mouse’s paws were placed on top of the fulcrum. The ventral face of the fulcrum was concave and the mouse’s abdomen was placed inside it. A sliding metaliferous rail was positioned under the mouse fulcrum. The axial distance between the mouse ovary and probe was 25.5 cm. At the right end of the chamber there was a cylindrical plastic prominence with a 1 cm diameter to ensure accurate targeting of the mouse ovary.
Comparison of outcomes between study groups
| Groups | Mice (n) | MII oocytes retrieved (n) | Parthenogenic oocytes | Fertilization rate (%) | Blastocysts (n) |
|---|---|---|---|---|---|
| 30 | 10.45 ± 0.74a, b | 1.66 ± 0.19 | 82.58 ± 4.54 | 33.81 ± 4.86q | |
| 27 | 13.17 ± 0.89b | 1.29 ± 0.20 | 79.64 ± 4.12 | 31.70 ± 4.05 | |
| 30 | 10.24 ± 0.57c, d | 1.73 ± 0.22 | 90.21 ± 4.36 | 25.05 ± 4.80b, c | |
| 28 | 12.53 ± 0.90d | 1.34 ± 0.21 | 82.45 ± 3.98 | 36.63 ± 4.35c | |
| 30 | 10.08 ± 0.59e | 1.85 ± 0.17a, b | 80.14 ± 4.82 | 19.95 ± 3.96a, b | |
| 29 | 11.77 ± 0.91 | 1.30 ± 0.20b | 75.98 ± 4.22 | 27.41 ± 3.77e | |
| 28 | 13.93 ± 0.89a,c, e | 1.34 ± 0.17a | 84 ± 4.15 | 38.50 ± 4.64bb, d, e | |
Values are mean ± SE. In each column, groups with at least one similar letter, have significant difference (p<0.05).
US; Mice in these experimental groups were irradiated one (US1), two (US2), and three (US3) times by US. Sham: Treatments in these groups were similar to the experiment groups except that the US device was turned off during exposure times.