Literature DB >> 24519710

Gap measurement in posterior-stabilized total knee arthroplasty with or without a trial femoral component.

Seiju Hayashi1, Yuji Murakami, Hiroyuki Inoue, Hiroo Nobutou, Koji Nishida, Yu Mochizuki.   

Abstract

PURPOSE: To investigate the effects of a trial femoral component on the intraoperative joint gap and intraoperative joint gap kinematics throughout the range of knee motion in minimally invasive surgery-total knee arthroplasty (MIS-TKA) with the gap technique.
MATERIALS AND METHODS: A total of 103 patients [15 men (15 knees) and 89 women (89 knees)] aged 50-88 years (mean 74.8 years) who received MIS-TKA with the gap technique were included. The intraoperative joint gap differences (90° flexion gap distance minus 0° extension gap distance) with and without the trial femoral component were compared. Subsequently, the intraoperative joint gap kinematics at 0°, 45°, 90°, and 120° with the trial femoral component were investigated.
RESULTS: The intraoperative component gap difference (4.4 ± 2.7 mm) was larger than the estimated joint gap difference (1.2 ± 1.9 mm) (p < 0.01). The mean intraoperative component gap distances at 0°, 45°, 90°, and 120° of knee flexion were 14.7 ± 2.6, 19.0 ± 3.2, 19.2 ± 3.4, and 16.6 ± 3.3 mm, respectively. The intraoperative component gap distance increased significantly from 0° extension to 90° of knee flexion (p < 0.01), and then decreased significantly toward deep knee flexion at 120° (p < 0.01).
CONCLUSIONS: The trial femoral component influenced the intraoperative gap measurements, and increased the intraoperative gap difference. The joint gap kinematics with the trial femoral component were not constant throughout the range of knee motion, even if the appropriate joint gaps in extension and flexion were achieved. For acquisition of constant stability throughout the knee motion, the present results should be taken into account by surgeons performing MIS-TKA with the gap technique.

Entities:  

Mesh:

Year:  2014        PMID: 24519710     DOI: 10.1007/s00402-014-1955-2

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  3 in total

1.  Accuracy of total knee arthroplasty using the modified gap technique based on the bone gap: an evaluation of the bone gap with a distal femoral trial component.

Authors:  Goki Kamei; Shigeki Ishibashi; Koki Yoshioka; Satoru Sakurai; Hiroyuki Inoue; Masakazu Ishikawa; Yu Mochizuki; Nobuo Adachi
Journal:  Arthroplasty       Date:  2021-04-05

2.  Tibiofemoral dynamic stressed gap laxities correlate with compartment load measurements in robotic arm-assisted total knee arthroplasty.

Authors:  Richard J Allom; Jil A Wood; Darren B Chen; Samuel J MacDessi
Journal:  Bone Jt Open       Date:  2021-11

3.  A gap balancing technique for adjusting the component gap in total knee arthroplasty using a navigation system.

Authors:  Hiroshi Takagi
Journal:  Asia Pac J Sports Med Arthrosc Rehabil Technol       Date:  2020-05-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.