Literature DB >> 24518902

Rapid detection of pesticides not amenable to multi-residue methods by flow injection-tandem mass spectrometry.

Hans G J Mol1, Ruud C J van Dam.   

Abstract

Flow injection combined with tandem mass spectrometry (MS/MS) was investigated for the rapid detection of highly polar pesticides that are not amenable to multi-residue methods because they do not partition into organic solvents and require dedicated chromatographic conditions. The pesticides included in this study were amitrole, chlormequat, cyromazine, daminozide, diquat, ethephon, fosetyl-Al, glufosinate, glyphosate and its metabolite aminomethylphosphonic acid, maleic hydrazide, mepiquat and paraquat. The composition of the flow-injection solvent was optimized to achieve maximum MS/MS sensitivity. Instrumental limits of detection varied between <0.05 and 1 pg. Fruit, vegetable, cereal, milk and kidney samples were extracted with water (1% formic acid in case of paraquat/diquat) and ten times diluted in either methanol/0.1% formic acid, methanol/0.1% ammonia or acetonitrile/0.1% ammonia, depending on the pesticide. The ion suppression observed depended strongly on both the matrix and the pesticide. This could be largely compensated for by matrix-matched calibration, but more accurate quantification was obtained by using isotopically labelled standards (commercially available for most of the pesticides studied). The method detection limits ranged from 0.02 mg/kg for chlormequat and mepiquat to 2 mg/kg for maleic hydrazide and were 0.05-0.2 mg/kg for most other pesticide/matrix combinations. This was sufficiently low to test compliance with EU maximum residue limits for many relevant pesticide/commodity combinations. The method substantially reduces the liquid chromatography-MS/MS capacity demand which for many laboratories is prohibitive for inclusion of these pesticides in their monitoring and surveillance programmes.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24518902     DOI: 10.1007/s00216-014-7644-8

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  4 in total

Review 1.  The Current Status of Analytical Methods Applied to the Determination of Polar Pesticides in Food of Animal Origin: A Brief Review.

Authors:  Emanuela Verdini; Ivan Pecorelli
Journal:  Foods       Date:  2022-05-23

2.  Hydrophilic Interaction Liquid Chromatography-Tandem Mass Spectrometry Analysis of Fosetyl-Aluminum in Airborne Particulate Matter.

Authors:  Francesca Buiarelli; Patrizia Di Filippo; Carmela Riccardi; Donatella Pomata; Riccardo Marsiglia; Carla Console; Daniele Puri
Journal:  J Anal Methods Chem       Date:  2018-03-01       Impact factor: 2.193

3.  Development and Application of a Novel Pluri-Residue Method to Determine Polar Pesticides in Fruits and Vegetables through Liquid Chromatography High Resolution Mass Spectrometry.

Authors:  Lorena Manzano-Sánchez; José Antonio Martínez-Martínez; Irene Domínguez; José Luis Martínez Vidal; Antonia Garrido Frenich; Roberto Romero-González
Journal:  Foods       Date:  2020-05-01

Review 4.  Flow Chemistry in Contemporary Chemical Sciences: A Real Variety of Its Applications.

Authors:  Marek Trojanowicz
Journal:  Molecules       Date:  2020-03-21       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.