Li-Di Quan1, Chao Xue1, Cheng-Gang Shao1, Shan-Qing Yang1, Liang-Cheng Tu1, Yong-Ji Wang2, Jun Luo1.
Abstract
The performance of the feedback control system is of central importance in the measurement of the Newton's gravitational constant G with angular acceleration method. In this paper, a PID (Proportion-Integration-Differentiation) feedback loop is discussed in detail. Experimental results show that, with the feedback control activated, the twist angle of the torsion balance is limited to [Formula: see text] at the signal frequency of 2 mHz, which contributes a [Formula: see text] uncertainty to the G value.Year: 2014 PMID: 24517789 DOI: 10.1063/1.4861189