Literature DB >> 24508545

One-pot ionic liquid-assisted synthesis of highly dispersed PtPd nanoparticles/reduced graphene oxide composites for nonenzymatic glucose detection.

Mian Li1, Xiangjie Bo1, Yufan Zhang1, Ce Han1, Liping Guo2.   

Abstract

A series of highly dispersed bimetallic PtPd alloy nanoparticles (NPs) anchored on reduced graphene oxide (RGO) have been synthesized with the assistance of ionic liquid (IL: [VEIM]BF4). Different ratios of (PtCl6)(2-) and (PdCl4)(2-) ions were firstly attached to IL functionalized graphene oxide (GO) sheets in ethylene glycol (EG), and then the encased metal ions and graphene oxide sheets were reduced simultaneously by EG with the assistance of microwave. The characterization results of scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), Raman spectroscopy, and X-ray diffraction (XRD) demonstrate that PtPd alloy NPs with small particle sizes are uniformly dispersed on RGO. Electrochemical measurements reveal that PtPd-IL-RGO modified electrode can directly catalyze glucose oxidation and display enhanced current response compared with PtPd-RGO (such as: a response time within 3s, a linear range from 0.1 to 22 mM at 0 V, good reproducibility, considerable stability, and excellent anti-interference to electroactive molecules and Cl(-)). The superior catalytic activity and selectivity make PtPd-IL-RGO nanomaterials very promising for applications in direct detection of glucose.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Ionic liquid; Nonenzymatic glucose detection; PtPd nanoparticle; Reduced graphene oxide

Mesh:

Substances:

Year:  2014        PMID: 24508545     DOI: 10.1016/j.bios.2014.01.030

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

Review 1.  A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors.

Authors:  Siva Kumar Krishnan; Eric Singh; Pragya Singh; Meyya Meyyappan; Hari Singh Nalwa
Journal:  RSC Adv       Date:  2019-03-18       Impact factor: 4.036

2.  Graphene-PtPd nanocomposite for low-potential-driven electrochemiluminescent determination of carcinoembryonic antigen using Ru(bpy)32.

Authors:  Lei Shang; Xiao-Hong Zhao; Wei Zhang; Li-Ping Jia; Rong-Na Ma; Qing-Wang Xue; Huai-Sheng Wang; Ai-Xiang Guo; Lei Si
Journal:  Mikrochim Acta       Date:  2021-12-06       Impact factor: 5.833

Review 3.  Biosensors Incorporating Bimetallic Nanoparticles.

Authors:  John Rick; Meng-Che Tsai; Bing Joe Hwang
Journal:  Nanomaterials (Basel)       Date:  2015-12-31       Impact factor: 5.076

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.