Towards local progression estimation of pulmonary emphysema using CT.

M Staring1, M E Bakker1, J Stolk2, D P Shamonin1, J H C Reiber1, B C Stoel1.   

Abstract

PURPOSE: Whole lung densitometry on chest CT images is an accepted method for measuring tissue destruction in patients with pulmonary emphysema in clinical trials. Progression measurement is required for evaluation of change in health condition and the effect of drug treatment. Information about the location of emphysema progression within the lung may be important for the correct interpretation of drug efficacy, or for determining a treatment plan. The purpose of this study is therefore to develop and validate methods that enable the local measurement of lung density changes, which requires proper modeling of the effect of respiration on density.
METHODS: Four methods, all based on registration of baseline and follow-up chest CT scans, are compared. The first naïve method subtracts registered images. The second employs the so-called dry sponge model, where volume correction is performed using the determinant of the Jacobian of the transformation. The third and the fourth introduce a novel adaptation of the dry sponge model that circumvents its constant-mass assumption, which is shown to be invalid. The latter two methods require a third CT scan at a different inspiration level to estimate the patient-specific density-volume slope, where one method employs a global and the other a local slope. The methods were validated on CT scans of a phantom mimicking the lung, where mass and volume could be controlled. In addition, validation was performed on data of 21 patients with pulmonary emphysema.
RESULTS: The image registration method was optimized leaving a registration error below half the slice increment (median 1.0 mm). The phantom study showed that the locally adapted slope model most accurately measured local progression. The systematic error in estimating progression, as measured on the phantom data, was below 2 gr/l for a 70 ml (6%) volume difference, and 5 gr/l for a 210 ml (19%) difference, if volume correction was applied. On the patient data an underlying linearity assumption relating lung volume change with density change was shown to hold (fitR(2) = 0.94), and globalized versions of the local models are consistent with global results (R(2) of 0.865 and 0.882 for the two adapted slope models, respectively).
CONCLUSIONS: In conclusion, image matching and subsequent analysis of differences according to the proposed lung models (i) has good local registration accuracy on patient data, (ii) effectively eliminates a dependency on inspiration level at acquisition time, (iii) accurately predicts progression in phantom data, and (iv) is reasonably consistent with global results in patient data. It is therefore a potential future tool for assessing local emphysema progression in drug evaluation trials and in clinical practice.

Entities:  

Mesh:

Year:  2014        PMID: 24506626     DOI: 10.1118/1.4851535

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  18 in total

1.  Standardizing CT lung density measure across scanner manufacturers.

Authors:  Huaiyu Heather Chen-Mayer; Matthew K Fuld; Bernice Hoppel; Philip F Judy; Jered P Sieren; Junfeng Guo; David A Lynch; Antonio Possolo; Sean B Fain
Journal:  Med Phys       Date:  2017-02-21       Impact factor: 4.071

2.  SPIROMICS Protocol for Multicenter Quantitative Computed Tomography to Phenotype the Lungs.

Authors:  Jered P Sieren; John D Newell; R Graham Barr; Eugene R Bleecker; Nathan Burnette; Elizabeth E Carretta; David Couper; Jonathan Goldin; Junfeng Guo; MeiLan K Han; Nadia N Hansel; Richard E Kanner; Ella A Kazerooni; Fernando J Martinez; Stephen Rennard; Prescott G Woodruff; Eric A Hoffman
Journal:  Am J Respir Crit Care Med       Date:  2016-10-01       Impact factor: 21.405

Review 3.  Progress in Imaging COPD, 2004 - 2014.

Authors:  David A Lynch
Journal:  Chronic Obstr Pulm Dis       Date:  2014-05-06

4.  Computed Tomography Image Matching in Chronic Obstructive Pulmonary Disease.

Authors:  Sandeep Bodduluri; Surya P Bhatt; Joseph M Reinhardt
Journal:  Crit Rev Biomed Eng       Date:  2016

Review 5.  Recent Advances in Computed Tomography Imaging in Chronic Obstructive Pulmonary Disease.

Authors:  Sandeep Bodduluri; Joseph M Reinhardt; Eric A Hoffman; John D Newell; Surya P Bhatt
Journal:  Ann Am Thorac Soc       Date:  2018-03

6.  Voxel-Wise Longitudinal Parametric Response Mapping Analysis of Chest Computed Tomography in Smokers.

Authors:  Wassim W Labaki; Tian Gu; Susan Murray; Charles R Hatt; Craig J Galbán; Brian D Ross; Carlos H Martinez; Jeffrey L Curtis; Eric A Hoffman; Esther Pompe; David A Lynch; Ella A Kazerooni; Fernando J Martinez; MeiLan K Han
Journal:  Acad Radiol       Date:  2018-07-26       Impact factor: 3.173

7.  Reprint of: Voxel-Wise Longitudinal Parametric Response Mapping Analysis of Chest Computed Tomography in Smokers.

Authors:  Wassim W Labaki; Tian Gu; Susan Murray; Charles R Hatt; Craig J Galbán; Brian D Ross; Carlos H Martinez; Jeffrey L Curtis; Eric A Hoffman; Esther Pompe; David A Lynch; Ella A Kazerooni; Fernando J Martinez; MeiLan K Han
Journal:  Acad Radiol       Date:  2019-02-18       Impact factor: 3.173

8.  Influence of Inspiratory/Expiratory CT Registration on Quantitative Air Trapping.

Authors:  Oliver Weinheimer; Benjamin A Hoff; Aleksa B Fortuna; Antonio Fernández-Baldera; Philip Konietzke; Mark O Wielpütz; Terry E Robinson; Craig J Galbán
Journal:  Acad Radiol       Date:  2018-12-10       Impact factor: 3.173

9.  Efficient methods for implementation of multi-level nonrigid mass-preserving image registration on GPUs and multi-threaded CPUs.

Authors:  Nathan D Ellingwood; Youbing Yin; Matthew Smith; Ching-Long Lin
Journal:  Comput Methods Programs Biomed       Date:  2016-01-06       Impact factor: 5.428

10.  Pulmonary ventilation imaging in asthma and cystic fibrosis using oxygen-enhanced 3D radial ultrashort echo time MRI.

Authors:  Wei Zha; Stanley J Kruger; Kevin M Johnson; Robert V Cadman; Laura C Bell; Fang Liu; Andrew D Hahn; Michael D Evans; Scott K Nagle; Sean B Fain
Journal:  J Magn Reson Imaging       Date:  2017-10-31       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.