Literature DB >> 24506595

Offline multiple adaptive planning strategy for concurrent irradiation of the prostate and pelvic lymph nodes.

Peng Qi1, Jean Pouliot2, Mack Roach2, Ping Xia1.   

Abstract

PURPOSE: Concurrent irradiation of the prostate and pelvic lymph nodes (PLNs) can be challenging due to the independent motion of the two target volumes. To address this challenge, the authors have proposed a strategy referred to as Multiple Adaptive Planning (MAP). To minimize the number of MAP plans, the authors' previous work only considered the prostate motion in one major direction. After analyzing the pattern of the prostate motion, the authors investigated a practical number of intensity-modulated radiotherapy (IMRT) plans needed to accommodate the prostate motion in two major directions simultaneously.
METHODS: Six patients, who received concurrent irradiation of the prostate and PLNs, were selected for this study. Nine MAP-IMRT plans were created for each patient with nine prostate contours that represented the prostate at nine locations with respect to the PLNs, including the original prostate contour and eight contours shifted either 5 mm in a single anterior-posterior (A-P), or superior-inferior (S-I) direction, or 5 mm in both A-P and S-I directions simultaneously. From archived megavoltage cone beam CT (MV-CBCT) and a dual imaging registration, 17 MV-CBCTs from 33 available MV-CBCT from these patients showed large prostate displacements (>3 mm in any direction) with respect to the pelvic bones. For each of these 17 fractions, one of nine MAP-IMRT plans was retrospectively selected and applied to the MV-CBCT for dose calculation. For comparison, a simulated isocenter-shifting plan and a reoptimized plan were also created for each of these 17 fractions. The doses to 95% (D95) of the prostate and PLNs, and the doses to 5% (D5) of the rectum and bladder were calculated and analyzed.
RESULTS: For the prostate, D95 > 97% of the prescription dose was observed in 16, 16, and 17 of 17 fractions for the MAP, isocenter-shifted, and reoptimized plans, respectively. For PLNs, D95 > 97% of the prescription doses was observed in 10, 3, and 17 of 17 fractions for the three types of verification plans, respectively. The D5 (mean ± SD) of the rectum was 45.78 ± 5.75, 45.44 ± 4.64, and 44.64 ± 2.71 Gy, and the D5 (mean ± SD) of the bladder was 45.18 ± 2.70, 46.91 ± 3.04, and 45.67 ± 3.61 Gy for three types of verification plans, respectively.
CONCLUSIONS: The MAP strategy with nine IMRT plans to accommodate the prostate motions in two major directions achieved good dose coverage to the prostate and PLNs. The MAP approach can be immediately used in clinical practice without requiring extra hardware and software.

Entities:  

Mesh:

Year:  2014        PMID: 24506595     DOI: 10.1118/1.4860663

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Stereotactic body radiotherapy to the prostate and pelvic lymph nodes: A detailed dosimetric analysis of a phase II prospective trial.

Authors:  Amar U Kishan; Marguerite Tyran; Julius Weng; Shrinivasa Upadhyaya; James Lamb; Michael Steinberg; Christopher King; Minsong Cao
Journal:  Br J Radiol       Date:  2019-04-03       Impact factor: 3.039

2.  Automated volumetric modulated arc therapy planning for whole pelvic prostate radiotherapy.

Authors:  Martin Buschmann; Abdul Wahab M Sharfo; Joan Penninkhof; Yvette Seppenwoolde; Gregor Goldner; Dietmar Georg; Sebastiaan Breedveld; Ben J M Heijmen
Journal:  Strahlenther Onkol       Date:  2017-12-21       Impact factor: 3.621

3.  Personalized Treatment Planning Automation in Prostate Cancer Radiation Oncology: A Comprehensive Dosimetric Study.

Authors:  Savino Cilla; Carmela Romano; Vittoria E Morabito; Gabriella Macchia; Milly Buwenge; Nicola Dinapoli; Luca Indovina; Lidia Strigari; Alessio G Morganti; Vincenzo Valentini; Francesco Deodato
Journal:  Front Oncol       Date:  2021-06-01       Impact factor: 6.244

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.