Literature DB >> 24503635

On the use of the Cramér-Rao lower bound for diffuse optical imaging system design.

Vivian Pera, Dana H Brooks, Mark Niedre.   

Abstract

We evaluated the potential of the Cramér-Rao lower bound (CRLB) to serve as a design metric for diffuse optical imaging systems. The CRLB defines the best achievable precision of any estimator for a given data model; it is often used in the statistical signal processing community for feasibility studies and system design. Computing the CRLB requires inverting the Fisher information matrix (FIM), however, which is usually ill-conditioned (and often underdetermined) in the case of diffuse optical tomography (DOT). We regularized the FIM by assuming that the inhomogeneity to be imaged was a point target and assessed the ability of point-target CRLBs to predict system performance in a typical DOT setting in silico. Our reconstructions, obtained with a common iterative algebraic technique, revealed that these bounds are not good predictors of imaging performance across different system configurations, even in a relative sense. This study demonstrates that agreement between the trends predicted by the CRLBs and imaging performance obtained with reconstruction algorithms that rely on a different regularization approach cannot be assumed a priori. Moreover, it underscores the importance of taking into account the intended regularization method when attempting to optimize source-detector configurations.

Mesh:

Year:  2014        PMID: 24503635      PMCID: PMC4019422          DOI: 10.1117/1.JBO.19.2.025002

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  21 in total

1.  Singular-value analysis and optimization of experimental parameters in fluorescence molecular tomography.

Authors:  Edward E Graves; Joseph P Culver; Jorge Ripoll; Ralph Weissleder; Vasilis Ntziachristos
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2004-02       Impact factor: 2.129

2.  Fluorescence optical diffusion tomography using multiple-frequency data.

Authors:  Adam B Milstein; Jonathan J Stott; Seungseok Oh; David A Boas; R P Millane; Charles A Bouman; Kevin J Webb
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2004-06       Impact factor: 2.129

3.  Statistical approach for detection and localization of a fluorescing mouse tumor in Intralipid.

Authors:  Adam B Milstein; Michael D Kennedy; Philip S Low; Charles A Bouman; Kevin J Webb
Journal:  Appl Opt       Date:  2005-04-20       Impact factor: 1.980

4.  Optimization of optode arrangements for diffuse optical tomography: A singular-value analysis.

Authors:  J P Culver; V Ntziachristos; M J Holboke; A G Yodh
Journal:  Opt Lett       Date:  2001-05-15       Impact factor: 3.776

5.  Estimation and statistical bounds for three-dimensional polar shapes in diffuse optical tomography.

Authors:  Gregory Boverman; Eric L Miller; Dana H Brooks; David Isaacson; Qianqian Fang; David A Boas
Journal:  IEEE Trans Med Imaging       Date:  2008-06       Impact factor: 10.048

6.  Methodology to optimize detector geometry in fluorescence tomography of tissue using the minimized curvature of the summed diffuse sensitivity projections.

Authors:  Robert W Holt; Frederic L Leblond; Brian W Pogue
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2013-08-01       Impact factor: 2.129

7.  Data-resolution based optimization of the data-collection strategy for near infrared diffuse optical tomography.

Authors:  Deepak Karkala; Phaneendra K Yalavarthy
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

8.  Optimization of source and detector configurations based on Cramer-Rao lower bound analysis.

Authors:  Ling Chen; Nanguang Chen
Journal:  J Biomed Opt       Date:  2011-03       Impact factor: 3.170

9.  Early-photon fluorescence tomography: spatial resolution improvements and noise stability considerations.

Authors:  Frederic Leblond; Hamid Dehghani; Dax Kepshire; Brian W Pogue
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2009-06       Impact factor: 2.129

10.  Statistical analysis of nonlinearly reconstructed near-infrared tomographic images: Part I--Theory and simulations.

Authors:  Brian W Pogue; Xiaomei Song; Tor D Tosteson; Troy O McBride; Shudong Jiang; Keith D Paulsen
Journal:  IEEE Trans Med Imaging       Date:  2002-07       Impact factor: 10.048

View more
  4 in total

1.  Multiplexed fluorescence tomography with spectral and temporal data: demixing with intrinsic regularization.

Authors:  Vivian Pera; Dana H Brooks; Mark Niedre
Journal:  Biomed Opt Express       Date:  2015-12-14       Impact factor: 3.732

2.  Optical property uncertainty estimates for spatial frequency domain imaging.

Authors:  Vivian Pera; Kavon Karrobi; Syeda Tabassum; Fei Teng; Darren Roblyer
Journal:  Biomed Opt Express       Date:  2018-01-18       Impact factor: 3.732

3.  System configuration optimization for mesoscopic fluorescence molecular tomography.

Authors:  Fugang Yang; Denzel Faulkner; Ruoyang Yao; Mehmet S Ozturk; Qinglan Qu; Xavier Intes
Journal:  Biomed Opt Express       Date:  2019-10-11       Impact factor: 3.732

4.  Sensitivity Uniformity Ratio as a New Index to Optimize the Scanning Geometry for Fluorescent Molecular Tomography.

Authors:  Anita Ebrahimpour; Seyed Salman Zakariaee; Marjaneh Hejazi
Journal:  J Med Signals Sens       Date:  2019 Jan-Mar
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.