Literature DB >> 24503251

Non-invasive in vivo characterization of microclimate pH inside in situ forming PLGA implants using multispectral fluorescence imaging.

Andreas Schädlich1, Sabine Kempe1, Karsten Mäder2.   

Abstract

The pH inside drug delivery systems influences directly the physical and chemical behavior of its ingredients specifically their solubility and stability. These properties significantly affect the release performance of the formulations as well as the pharmacological effect. Therefore, the determination of the microclimate pH (μpH) inside the drug delivery systems is of great importance and interest. Implants are considered to be attractive parenteral drug delivery systems used for the long-term application of drugs and of peptides. Poly(lactide-co-glycolide) (PLGA) is the most frequently used and extensively researched polymer for implant preparation. However it is known that the microclimate pH (μpH) within the PLGA implants can also drop dramatically. This pH drop can cause peptide or protein instabilities as well as drug insolubilities and further decomposition. Although the internal pH behavior of PLGA implants and microparticles has been studied in vitro, no data about the μpH behavior in in situ forming implants has yet been described. This is due to the fact, that there is no reliable non-invasive method available to measure directly and continuously the pH in vivo. Therefore, the question if in vitro measurement results are potentially assignable remains unclear. In this study, the μpH of in situ forming PLGA implants were mapped in vitro, in vivo, and ex vivo. A non-invasive in vivo pH measurement method using the multispectral Maestro fluorescence imaging system was developed. The in vivo experiments performed, not only enabled the authors of this article to make certain assumptions about μpH behavior but also emphasized certain expectations regarding the solvent replacement in the core area of the implant as well as the release profile of hydrophilic substances. The experiments emphasized the broad application range of the fluorescence imaging technique for non-invasive monitoring of μpH values in drug delivery systems in vivo.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  PLGA; fluorescence imaging; in situ forming implants; in vivo imaging; microclimate pH; pH distribution

Mesh:

Substances:

Year:  2014        PMID: 24503251     DOI: 10.1016/j.jconrel.2014.01.024

Source DB:  PubMed          Journal:  J Control Release        ISSN: 0168-3659            Impact factor:   9.776


  6 in total

1.  The Effect of Additives on the Behavior of Phase Sensitive In Situ Forming Implants.

Authors:  Luis Solorio; Divya Sundarapandiyan; Alex Olear; Agata A Exner
Journal:  J Pharm Sci       Date:  2015-07-14       Impact factor: 3.534

Review 2.  Biomedical Imaging in Implantable Drug Delivery Systems.

Authors:  Haoyan Zhou; Christopher Hernandez; Monika Goss; Anna Gawlik; Agata A Exner
Journal:  Curr Drug Targets       Date:  2015       Impact factor: 3.465

3.  Characterization of nanostructured ureteral stent with gradient degradation in a porcine model.

Authors:  Xiaoqing Wang; Hongli Shan; Jixue Wang; Yuchuan Hou; Jianxun Ding; Qihui Chen; Jingjing Guan; Chunxi Wang; Xuesi Chen
Journal:  Int J Nanomedicine       Date:  2015-04-20

4.  Safety and audiological outcome in a case series of tertiary therapy of sudden hearing loss with a biodegradable drug delivery implant for controlled release of dexamethasone to the inner ear.

Authors:  Stefan K Plontke; Arne Liebau; Eric Lehner; Daniel Bethmann; Karsten Mäder; Torsten Rahne
Journal:  Front Neurosci       Date:  2022-09-20       Impact factor: 5.152

Review 5.  Poly(lactic-co-glycolic acid) microsphere production based on quality by design: a review.

Authors:  Yabing Hua; Yuhuai Su; Hui Zhang; Nan Liu; Zengming Wang; Xiang Gao; Jing Gao; Aiping Zheng
Journal:  Drug Deliv       Date:  2021-12       Impact factor: 6.819

6.  Tabotamp®, Respectively, Surgicel®, Increases the Cell Death of Neuronal and Glial Cells In Vitro.

Authors:  Sandra Leisz; Marie-Luise Trutschel; Karsten Mäder; Christian Scheller; Christian Strauss; Sebastian Simmermacher
Journal:  Materials (Basel)       Date:  2020-05-28       Impact factor: 3.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.