Literature DB >> 24503236

Comparison between oscillometric and intra-arterial blood pressure measurements in ill preterm and full-term neonates.

Shwetal Lalan1, Douglas Blowey2.   

Abstract

Conflicting data exist regarding the accuracy of the oscillometric method of blood pressure (BP) measurement in neonates. There is limited data regarding intra-arterial BP trends in neonates. We aimed to determine the accuracy of oscillometric BP measurements and to evaluate the BP distributions in ill neonates. A total of 1492 simultaneously obtained oscillometric and intra-arterial (umbilical arterial [UAC] or radial arterial) BP measurements were used for comparisons and 125,580 intra-arterial BP readings were used to the evaluate BP distribution. There was a statistically significant difference (P < .0001) between the oscillometric and radial mean arterial BP (MAP) 4.8 ± 9.8 mm Hg, systolic BP 8.3 ± 11.6 mm Hg, diastolic BP 4.3 ± 9.3 mm Hg and between the oscillometric and UAC systolic BP 5.2 ± 11.9 mm Hg and diastolic BP -0.8 ± 10.4 mm Hg. The MAP increased with increases in weight (35.3 ± 4.92 mm Hg/kg), post-menstrual age (-0.29 ± 1.41 mm Hg/week) and advanced gestational age at birth (13.12 ± 0.90 mm Hg/week). Oscillometric BP measurements are not equivalent to the intra-arterial (UAC or radial arterial) BP in ill neonates. The BP increases with increase in weight, gestational age at birth, and post-menstrual age in ill neonates.
Copyright © 2014 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

Keywords:  Accuracy; invasive blood pressure; non-invasive blood pressure

Mesh:

Year:  2013        PMID: 24503236     DOI: 10.1016/j.jash.2013.10.003

Source DB:  PubMed          Journal:  J Am Soc Hypertens        ISSN: 1878-7436


  5 in total

1.  Neonatal hypertension: an educational review.

Authors:  Matthew W Harer; Alison L Kent
Journal:  Pediatr Nephrol       Date:  2018-07-05       Impact factor: 3.714

2.  Effects of preterm birth and ventilation on glomerular capillary growth in the neonatal lamb kidney.

Authors:  Megan R Sutherland; Danica Ryan; Mar Janna Dahl; Kurt H Albertine; Mary Jane Black
Journal:  J Hypertens       Date:  2016-10       Impact factor: 4.844

3.  Bioreactance-derived haemodynamic parameters in the transitional phase in preterm neonates: a longitudinal study.

Authors:  Lizelle Van Wyk; Johan Smith; John Lawrenson; Carl J Lombard; Willem Pieter de Boode
Journal:  J Clin Monit Comput       Date:  2021-05-13       Impact factor: 1.977

4.  Discrepancy between invasive and non-invasive blood pressure readings in extremely preterm infants in the first four weeks of life.

Authors:  Tobias Werther; Lukas Aichhorn; Sigrid Baumgartner; Angelika Berger; Katrin Klebermass-Schrehof; Ulrike Salzer-Muhar
Journal:  PLoS One       Date:  2018-12-28       Impact factor: 3.240

5.  Effects of tilt on cerebral hemodynamics measured by NeoDoppler in healthy neonates.

Authors:  Anders Hagen Jarmund; Siv Steinsmo Ødegård; Hans Torp; Siri Ann Nyrnes
Journal:  Pediatr Res       Date:  2021-01-27       Impact factor: 3.756

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.