Literature DB >> 24496443

Implementation of smart pump technology in a paediatric intensive care unit.

Silvia Manrique-Rodríguez1, Amelia C Sánchez-Galindo2, Ana de Lorenzo-Pinto2, Leticia González-Vives2, Jesús López-Herce2, Ángel Carrillo-Álvarez2, María Sanjurjo-Sáez2, Cecilia M Fernández-Llamazares2.   

Abstract

Patient safety is a matter of major concern that involves every health professional. Nowadays, emerging technologies such as smart pumps can diminish medication errors as well as standardise and improve clinical practice with the subsequent benefits for patients. The aim of this paper was to describe the smart pump implementation process in a paediatric intensive care unit (PICU) and to present the most relevant infusion-related programming errors that were prevented. This was a comparative study between CareFusion Alaris Guardrails(®) and Hospira MedNet(®) systems, as well as a prospective and intervention study with analytical components carried out in the PICU of Gregorio Marañón General and Teaching Hospital. All intravenous infusions programmed with a pump in the eleven beds of the unit were analyzed. A drug library was developed and subsequently loaded into CareFusion and Hospira pumps that were used during a three month period each. The most suitable system for implementation was selected according to their differences in features and users' acceptance. Data stored in the pumps were analyzed to assess user compliance with the technology, health care setting and type of errors intercepted. The implementation process was carried out with CareFusion systems. Compliance with the technology was 92% and user acceptance was high. Vacation substitution and drug administration periods were significantly associated with a greater number of infusion-related programming errors. High risk drugs were involved in 48% of intercepted errors. Based on these results we can conclude that implementation of smart pumps proved effective in intercepting infusion-related programming errors from reaching patients. User awareness of the importance of programming infusions with the drug library is the key to succeed in the implementation process.
© The Author(s) 2013.

Entities:  

Keywords:  drug library; intravenous administration; programming errors; safety; smart pumps

Mesh:

Year:  2014        PMID: 24496443     DOI: 10.1177/1460458213518058

Source DB:  PubMed          Journal:  Health Informatics J        ISSN: 1460-4582            Impact factor:   2.681


  2 in total

1.  The impact of drug error reduction software on preventing harmful adverse drug events in England: a retrospective database study.

Authors:  Adam Sutherland; William S Gerrard; Arif Patel; Michelle Randall; Emma Weston
Journal:  BMJ Open Qual       Date:  2022-07

2.  Smart pumps and random safety audits in a Neonatal Intensive Care Unit: a new challenge for patient safety.

Authors:  Elena Bergon-Sendin; Carmen Perez-Grande; David Lora-Pablos; María Teresa Moral-Pumarega; Ana Melgar-Bonis; Carmen Peña-Peloche; Mercedes Diezma-Rodino; Lidia García-San Jose; Esther Cabañes-Alonso; Carmen Rosa Pallas-Alonso
Journal:  BMC Pediatr       Date:  2015-12-11       Impact factor: 2.125

  2 in total