Literature DB >> 24496169

Minimum effective volume of combined lidocaine-bupivacaine for analgesic subparaneural popliteal sciatic nerve block.

Wallaya Techasuk1, Francisca Bernucci, Tracy Cupido, Andrea P González, José A Correa, Roderick J Finlayson, De Q H Tran.   

Abstract

BACKGROUND AND OBJECTIVES: The aim of this study was to determine the minimum effective volume (MEV) of combined lidocaine 1.0%-bupivacaine 0.25% with epinephrine 5 μg/mL in 90% of patients (MEV90) for ultrasound-guided subparaneural popliteal sciatic nerve block.
METHODS: All subjects received an ultrasound-guided subparaneural popliteal sciatic nerve block (at the neural bifurcation) with combined lidocaine 1.0%-bupivacaine 0.25% and epinephrine 5 μg/mL. Using an out-of-plane technique, a 17-gauge, 8-cm Tuohy needle was advanced until its tip was positioned between the tibial and peroneal nerves inside the paraneural sheath. Volume assignment was carried out using a biased coin design, up-and-down sequential method, where the volume of local anesthetic administered to each patient depended on the response of the previous one. In case of failure, the next subject received a higher volume (defined as the previous volume with an increment of 3.0 mL). If the previous patient had a successful block, the next subject was randomized to a lower volume (defined as the previous volume with a decrement of 3.0 mL), with a probability of b = 0.11, or the same volume, with a probability of 1 - b = 0.89. Using a composite scale encompassing sensory and motor block, success was defined, at 30 minutes, as a minimal score of 6 points (out of 8 points). The 6-point score was intended to mirror successful postoperative analgesia. Patients undergoing surgery of the leg, ankle, or foot were prospectively enrolled until 45 successful blocks were obtained.
RESULTS: Fifty-two patients were recruited for this study. Using isotonic regression and bootstrap confidence interval, the MEV90 of combined lidocaine 1.0%-bupivacaine 0.25% with epinephrine 5 μg/mL was estimated to be 13.3 mL (95% confidence interval, 10.2-16.4 mL).
CONCLUSIONS: For ultrasound-guided subparaneural (analgesic) popliteal sciatic nerve block, the MEV90 of combined lidocaine 1.0%-bupivacaine 0.25% with epinephrine 5 μg/mL is 13.3 mL (95% confidence interval, 10.2-16.4 mL).

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24496169     DOI: 10.1097/AAP.0000000000000051

Source DB:  PubMed          Journal:  Reg Anesth Pain Med        ISSN: 1098-7339            Impact factor:   6.288


  5 in total

Review 1.  Ultrasound-guided regional anaesthesia in foot and ankle surgery.

Authors:  Herbert Gbejuade; Josephine Squire; Anindya Dixit; Vipul Kaushik; Jitendra Mangwani
Journal:  J Clin Orthop Trauma       Date:  2020-02-26

2.  Low-dose lidocaine attenuates fentanyl-induced cough: A double-blind randomized controlled trial.

Authors:  Nuanwan Phuvachoterojanaphokin; Grit Watanaboonyongcharoen; Sarita Jinawong; Sithapan Munjupong
Journal:  Eur J Clin Pharmacol       Date:  2022-01-28       Impact factor: 2.953

3.  Minimum effective local anesthetic volume for surgical anesthesia by subparaneural, ultrasound-guided popliteal sciatic nerve block: A prospective dose-finding study.

Authors:  Seung Uk Bang; Dong Ju Kim; Jin Ho Bae; Kyudon Chung; Yeesuk Kim
Journal:  Medicine (Baltimore)       Date:  2016-08       Impact factor: 1.889

4.  Estimation of the minimum effective volume of 0.5% bupivacaine for ultrasound-guided popliteal sciatic nerve block in diabetic patients with neuropathy.

Authors:  Srinivasan Parthasarathy; Avijit Chanda; Balachandar Saravanan
Journal:  Indian J Anaesth       Date:  2022-07-22

5.  Efficacy of ultrasound-guided fascia iliaca compartment block after hip hemiarthroplasty: A prospective, randomized trial.

Authors:  Seunguk Bang; Jihyun Chung; Jaejung Jeong; Hahyeon Bak; Dongju Kim
Journal:  Medicine (Baltimore)       Date:  2016-09       Impact factor: 1.889

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.