Hun Lee1, Kwanghyun Lee, Ji Min Ahn, Eung Kweon Kim, Bradford Sgrignoli, Tae-Im Kim. 1. *MD †MD, PhD ‡DO Department of Ophthalmology, Institute of Vision Research, Yonsei University College of Medicine, Seoul, Korea (HL, KL, JMA, EKK, BS, T-iK); and Department of Ophthalmology, Corneal Dystrophy Research Institute, Severance Biomedical Science Institute, Brain Korea 21 Project for Medical Science, Yonsei University College of Medicine, Seoul, Korea (EKK).
Abstract
PURPOSE: To compare the optical quality measurements obtained from the double-pass system and ocular aberrations, subjective visual acuity, and contrast sensitivity score in pseudophakic eyes. METHODS: Three months after cataract surgery, modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scatter index, and objective pseudoaccommodation obtained from the double-pass system were compared with total aberration, higher-order aberration, and spherical aberration obtained from ray-tracing aberrometer. In addition, parameters of the double-pass system were compared with subjective visual acuity and the contrast sensitivity score. RESULTS: Forty eyes of 40 patients were included. The MTF cutoff frequency and Strehl ratio were negatively correlated with total aberration (r = -0.503, p = 0.003; r = -0.509, p = 0.003, respectively) and subjective visual acuity (r = -0.453, p = 0.007; r = -0.354, p = 0.040, respectively). The objective scatter index was positively correlated with total aberration (r = 0.451, p = 0.024) and subjective visual acuity (r = 0.516, p = 0.008). The MTF cutoff frequency showed a correlation with contrast sensitivity score under photopic and mesopic conditions. CONCLUSIONS: Optical quality parameters obtained from the double-pass system were correlated with ocular aberrations, subjective visual acuity, and contrast sensitivity score in pseudophakic eyes.
PURPOSE: To compare the optical quality measurements obtained from the double-pass system and ocular aberrations, subjective visual acuity, and contrast sensitivity score in pseudophakic eyes. METHODS: Three months after cataract surgery, modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scatter index, and objective pseudoaccommodation obtained from the double-pass system were compared with total aberration, higher-order aberration, and spherical aberration obtained from ray-tracing aberrometer. In addition, parameters of the double-pass system were compared with subjective visual acuity and the contrast sensitivity score. RESULTS: Forty eyes of 40 patients were included. The MTF cutoff frequency and Strehl ratio were negatively correlated with total aberration (r = -0.503, p = 0.003; r = -0.509, p = 0.003, respectively) and subjective visual acuity (r = -0.453, p = 0.007; r = -0.354, p = 0.040, respectively). The objective scatter index was positively correlated with total aberration (r = 0.451, p = 0.024) and subjective visual acuity (r = 0.516, p = 0.008). The MTF cutoff frequency showed a correlation with contrast sensitivity score under photopic and mesopic conditions. CONCLUSIONS: Optical quality parameters obtained from the double-pass system were correlated with ocular aberrations, subjective visual acuity, and contrast sensitivity score in pseudophakic eyes.
Authors: Joaquín Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Ana Tauste; David P Piñero Journal: J Ophthalmol Date: 2018-06-27 Impact factor: 1.909
Authors: Miriam Casares-López; José J Castro-Torres; Sonia Ortiz-Peregrina; Francesco Martino; Carolina Ortiz Journal: Int J Environ Res Public Health Date: 2021-06-24 Impact factor: 3.390