Literature DB >> 24492739

Improvement of T1 contrast in whole-brain black-blood imaging using motion-sensitized driven-equilibrium prepared 3D turbo spin echo (3D MSDE-TSE).

Masami Yoneyama1, Masanobu Nakamura, Taro Takahara, Atsushi Takemura, Makoto Obara, Takashi Tabuchi, Satoshi Tatsuno, Seishi Sawano.   

Abstract

We demonstrated a new scheme for performing the T1-enhanced whole-brain black-blood imaging pulse sequence using motion-sensitized driven-equilibrium prepared 3-dimensional (3D) turbo spin echo (MSDE-TSE) with anti-driven-equilibrium post pulse. The use of an anti-driven-equilibrium pulse considerably improved the T1 contrast of MSDE-TSE black-blood images. This sequence can be used for whole-brain 3D volumetric T1-weighted black-blood imaging and may improve the accuracy of anatomical localization for certain brain lesions.

Mesh:

Substances:

Year:  2014        PMID: 24492739     DOI: 10.2463/mrms.2013-0047

Source DB:  PubMed          Journal:  Magn Reson Med Sci        ISSN: 1347-3182            Impact factor:   2.471


  5 in total

1.  Magnetic resonance post-contrast vascular hyperintensities at 3 T: a new highly sensitive sign of vascular occlusion in acute ischaemic stroke.

Authors:  Loïc Duron; Julien Savatovsky; Michael Obadia; Marie Astrid Metten; Pascal Roux; Raphael Blanc; Jean-Claude Sadik; Sarah Dhundass; Augustin Lecler
Journal:  Eur Radiol       Date:  2018-02-09       Impact factor: 5.315

2.  Improved motion-sensitized driven-equilibrium preparation for 3D turbo spin echo T1 weighted imaging after gadolinium administration for the detection of brain metastases on 3T MRI.

Authors:  Sangjoon Lee; Dong Woo Park; Ji Young Lee; Young-Jun Lee; Taeyoon Kim
Journal:  Br J Radiol       Date:  2016-05-17       Impact factor: 3.039

3.  Comparison of contrast-enhanced modified T1-weighted 3D TSE black-blood and 3D MP-RAGE sequences for the detection of cerebral metastases and brain tumours.

Authors:  N N Kammer; E Coppenrath; K M Treitl; H Kooijman; O Dietrich; T Saam
Journal:  Eur Radiol       Date:  2015-09-03       Impact factor: 5.315

4.  Efficacy of Maximum Intensity Projection of Contrast-Enhanced 3D Turbo-Spin Echo Imaging with Improved Motion-Sensitized Driven-Equilibrium Preparation in the Detection of Brain Metastases.

Authors:  Yun Jung Bae; Byung Se Choi; Kyung Mi Lee; Yeon Hong Yoon; Leonard Sunwoo; Cheolkyu Jung; Jae Hyoung Kim
Journal:  Korean J Radiol       Date:  2017-05-19       Impact factor: 3.500

5.  High-resolution magnetic resonance imaging of intracranial vessel walls: Comparison of 3D T1-weighted turbo spin echo with or without DANTE or iMSDE.

Authors:  Se Jin Cho; Seung Chai Jung; Chong Hyun Suh; Jung Bin Lee; Donghyun Kim
Journal:  PLoS One       Date:  2019-08-06       Impact factor: 3.240

  5 in total